REINSTATEMENT OF PERMIT NO 101041725 MUST BEGIN WORK AND OR REQUEST INSPECTIONS NO LATER THAN JULY 2026 ON PERMIT NO. 101041725
SPR 2019 CBRC: SECOND FLOOR ADDITION TO EXISTING MASONRY GARAGE TO INCLUDE 1 ADU.
LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 200 AMP SERVICE DISCONNECTING MEANS WITH 12 CIRCUITS. RECEPTACLE OUTLETS: 45 . LIGHTING OUTLETS: 18. SPECIFIC LOCATION: BASEMENT, 1ST FLOOR, LOFT, AND EXTERIOR.
ELECTRICAL MAINTENANCE PERMIT. OCCUPANCY: BUSINESS. START DATE: 4/1/2026. END DATE: 5/1/2026. ALL WORK UNDER THIS PERMIT MUST BE PERFORMED BY EMPLOYEES OF THE LISTED ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR MUST MAINTAIN COMPLETE WRITTEN RECORDS OF ALL WORK PERFORMED UNDER THIS PERMIT AND MAKE THOSE RECORDS AVAILABLE TO THE BUILDING COMMISSIONER UPON REQUEST.
LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 100 AMP SERVICE DISCONNECTING MEANS WITH 30 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 1. SPECIFIC LOCATION: BASEMENT AND REAR OF HOME.
TUCKPOINTING AND UNIT MASONRY REPAIR / REPLACEMENT: 500 SQ. FT., LINTEL QTY. 0, MAX. LENGTH 0. LOCATION: NEAR ROOF.
SCOPE: ROOF REPLACEMENT. AREA: 2502 SQ. FT. ROOF COVERING: OTHER. LOCATION: ROOF - HOME ONLY. IL ROOFING CONTRACTOR LICENSE: 104020004.
LOW VOLTAGE/COMMUNICATION ELECTRICAL WORK. INSTALL DATA/VIDEO. SPECIFIC LOCATION: SUITE 1521.
2019 SPR - INSTALLATION OF 20.65 KW SYSTEM USING (35) HANWHA PV MODULES OR EQUIVALENT WITH 590 WATTS OF POWER EACH ON ROOF OF EXISTING 5-STORY RESIDENTIAL BUILDING.
SELF-CERT 2019 CBRC: INTERIOR ALTERATIONS OF COMMERCIAL SPACE INTO NEW CASH AMERICA PAWN SHOP, MEP AS PER PLANS.(OCCUPANCY GROUP M, CONSTRUCTION TYPE III-A)
TUCKPOINTING AND UNIT MASONRY REPAIR / REPLACEMENT: 4800 SQ. FT., LINTEL QTY. 0, MAX. LENGTH 0. LOCATION: EXTERIOR WALLS.
LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 100 AMP SERVICE DISCONNECTING MEANS WITH 12 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 0. SPECIFIC LOCATION: APARTMENT# 1401.
TEMPORARY SCAFFOLDING: QTY: 4, MAX. LENGTH: 360 FT., MAX. HEIGHT: 155 FT. LOCATION: SIDEWALK ON STATE ST AND LAKE ST. PERMIT EXPIRATION DATE: 365 DAYS FROM PERMIT ISSUED DATE THIS PERMIT IS NOT VALID WITHOUT CORRESPONDING CDOT PUBLIC WAY PERMIT.
ELECTRICAL MAINTENANCE PERMIT. OCCUPANCY: BUSINESS. START DATE: 4/1/2026. END DATE: 5/1/2026. ALL WORK UNDER THIS PERMIT MUST BE PERFORMED BY EMPLOYEES OF THE LISTED ELECTRICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR MUST MAINTAIN COMPLETE WRITTEN RECORDS OF ALL WORK PERFORMED UNDER THIS PERMIT AND MAKE THOSE RECORDS AVAILABLE TO THE BUILDING COMMISSIONER UPON REQUEST.
LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 100 AMP SERVICE DISCONNECTING MEANS WITH 30 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 1. SPECIFIC LOCATION: BASEMENT AND REAR OF HOME.
FOR PERMIT 101063777: REPLACEMENT OTHER CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE.
SCOPE: NONSTRUCTURAL INTERIOR ALTERATION TO EXISTING SUITE FOR INSTALLATION OF SECOND EGRESS.LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), SUITE 1600 - 1ST FLOOR.
SPR 2019 CBRC: ALTERATIONS TO RELATED WORK TO REAR ENCLOSED PORCH STRUCTURRE FORMING A 2 STORY FRAME ADDITION OF SFR;REMOVE PARTIAL REAR ENCLOSURE & REPLACE W/NEW REAR WOOD STAIRS PER PLANS INCLUDING MASONRY WORK ON THE SOUTH AND WEST ELEVATION OF THE BUILDING AS PER PLANS AND ADDRESS BUILDING VIOLATIONS TO 2 STORY REAR ADDITION (OCCUPANCY: R5; CONST. TYPE: IIIA) - NO PLUMBING WORK UNDER THIS PERMIT**CERTIFIED CORRECTIONS SUBJECT TO FIELD INSPECTIONS & AUDIT **
LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 100 AMP SERVICE DISCONNECTING MEANS WITH 1 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 1. SPECIFIC LOCATION: REAR OF THE PROPERTY AND BASEMENT.
FOR PERMIT 101043797: REPLACEMENT GENERAL CONTRACTOR. REPLACEMENT ELECTRICAL CONTRACTOR. REPLACEMENT PLUMBING CONTRACTOR. REPLACEMENT OTHER CONTRACTOR. NEW CONTRACTOR(S) LISTED UNDER "OTHER APPLICANTS AND CONTRACTORS" ON PERMIT CERTIFICATE. CHANGE OF OWNER FOR PERMIT 101043797. NEW OWNER LISTED ON THIS PERMIT.
NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 22'-0' ' X22'-0' '. HIP ROOF HEIGHT TO PEAK: 14'-0' '.
THIRD REVISION PERMIT TO THE SECOND REVISION PERMIT #101062734, FIRST REVISED PERMIT #101038071, AND TO THE ORIGINAL PERMIT #100987429 TO REVISE THE SOLAR INVERTER LOCATIONS AND ASSOCIATED CONDUITS. THEY WILL BE RELOCATED FROM EQUIPMENT RACKS NEAR THE SW SIDE OF THE ROOF TO BE DISPERSED THROUGHOUT THE SOLAR ARRAYS. APPROXIMATELY 500 SQ FEET OF THE ROOF AREA WILL BE CHANGING. THE SOLAR RACKING, PANELS, AND OTHER ELECTRICAL EQUIPMENT REMAIN UNCHANGED. THE FOLLOWING SHEETS ARE BEING SUBMITTED WITH
SELF-CERT 2019 CBRC: FULL FLOOR DEMO TO EXISTING TENANT BUILDOUT ON THE 10TH FLOOR. DEMOLITION OF INTERIOR PARTITIONS, CEILINGS, FLOORS, FIXTURES, AND FINISHES. 1A CONSTRUCTION, B-BUSINESS OCCUPANCY.
LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 100 AMP SERVICE DISCONNECTING MEANS WITH 30 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 1. SPECIFIC LOCATION: BASEMENT AND REAR OF HOME.
REPAIR OR IN-KIND REPLACEMENT OF 4 PLUMBING FIXTURES AS DESCRIBED IN PERMIT APPLICATION. INCLUDES REPAIR OR REPLACMENT OF PLUMBING PIPING. LOCATIONS: 0 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), 2 INTERIOR COMMON AREAS, COMMUNITY KITCHEN & BASEMENT.
INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 10 KW. ARRAY OUTPUT: 5.265 KW. INCLUDES 15 KWH ENERGY STORAGE SYSTEM. LOCATION: ROOF PLANES OF HOME. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.
LINE VOLTAGE ELECTRICAL WORK. REPAIR OR ALTER DEVICES ON EXISTING CIRCUITS. RECEPTACLE OUTLETS: 15 . LIGHTING OUTLETS: 0. SPECIFIC LOCATION: GATE T3, T5.
LINE VOLTAGE ELECTRICAL WORK. REPAIR OR ALTER DEVICES ON EXISTING CIRCUITS. RECEPTACLE OUTLETS: 0 . LIGHTING OUTLETS: 230. SPECIFIC LOCATION: RESIDENTIAL UNITS.
FIRE ALARM: MODIFICATION OF EXISTING SYSTEM. ASSOCIATED BUILDING PERMIT:101068949. AFFECTS: 0 DWELLING UNITS; 1 NON-RESIDENTIAL UNITS. HIGH-RISE BUILDING: YES. VOICE COMMUNICATION: NO. SPECIAL LOCKING: YES. MONITORING TYPE: CITY FIRE ALARM BOX CONNECTION . SPECIFIC LOCATION: FLOOR 34.
LINE VOLTAGE ELECTRICAL WORK. NEW TEMPORARY 200 AMP SERVICE DISCONNECTING MEANS WITH 2 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 1. SPECIFIC LOCATION: PARKING LOT.