• Removal of existing checkouts. • New checkouts (belted and self-checkout). • New/relocated gondolas and fixtures. • Relocate existing chicken warmer. • Removal of grab and go cases with chase and railings. • Potential impacts to RCU on roof (removal, cap). Plumbing - cap/plug floor drains.
9433 Flatwoods Park Trl, Thonotosassa FL 33592
TENANT BUILD-OUT OF NEW RAD TECH AND SURG TECH CLASSROOM SPACES. X-RAY EQUIPMENT TO BE PROVIDED AT A FUTURE DATE. REPLACEMENT OF THE RECEPTION DESK.
Installation of a wall-LED sign using existing electrical wiring; no new electrical work required.
Installation of one illuminated monument sign and connect to existing electric. VAR 25-1369.
Installation of one illuminated pylon sign and connect to existing electric. VAR 25-1369.
Install feeders and new 200a 480v panel. Install circuits and disconnects for 5 future portable cooling trailers
Change of Use Occupancy from Group B to Group M for Retail Use. No building or structural alterations planned. Exterior electrical work to be done and roll up doors to be installed for exterior canopy.
Two new ground up type II-B construction (2) story above grade and basement buildings. Building 2, 54,706 SF. Scope includes civil under PMT25-14545 and meters, building, full MEP's, and finishes. Deferred fire sprinkler, fire alarm, electric vehicle gates, and elevator. Special Inspections Req for structural items, post-installed anchors, steel, concrete, masonry, soils, cold-formed light gauge steel, and ERRC. Reviewed with comments. Results in a CoO.
Install 5 steel shade structures with fabric covers in new community development. Structure A (1,553 SF), Structure B (1,920 SF), Structure C (2x 4,185 SF), and Structure D (308 SF). Total Canopy coverage 12,151 SF. Special inspections required: Fabricated items, Steel Construction, Concrete Construction, and Driven Deep Foundations. Results in CofC.
Modify existing hood fire suppression system to include nozzle adjustment over existing range for proper coverage. Third-party inspection report provided.
1. REMOVE EXISTING DEDICATED FUNCTION PANEL AND REPLACE WITH A NEW DEDICATED FUNCTION CONTROL UNIT FOR SPRINKLER WATERFLOW AND SUPERVISORY MONITORING. 2. CONTROL UNIT TO BE RELOCATED BY EXISTING FIRE SPRINKLER RISERS. 3. PROVIDE (3) RELAYS FOR BIG ASS FAN'S TO SHUT DOWN ON GENERAL ALARM
like for like replacement 400-amp panel
Install of new 111 SF, type II-B construction with 2hr wall rating, group H-3 occupancy pre-manufactured chemical storage bldg. Scope to include structural 768 SF of foundation and concrete curb and electrical power distribution from exist SES and meter. REF: ADM26-00222 for the planning review of this scope. Deferred fire suppression and fire alarm. Approved as noted. Results in CoO.
Occupancy verification for existing 3,360 SF, type VB construction, B occupancy for funeral home with 500 SF covered outdoor area. No construction being performed. Approved as noted. Max occupant load signage posting in building required. Result in CoO. EXPEDITE - CHANGE OF OCCUPANCY
(2) new 78 SF Steel Smoking Shelters to be installed per engineered plans. Occupancy Type 'U'.
Two new ground up type II-B construction (2) story above grade and basement buildings. Building 1, 53,952 SF. Scope includes civil, building, full MEP's, and finishes. New 3/4-inch domestic and 1-inch landscape water meter. New 800 amp 3-phase electric meter. Deferred fire sprinkler, fire alarm, electric vehicle gates, and elevator. Special Inspections Req for structural items, post-installed anchors, steel, concrete, masonry, soils, cold-formed light gauge steel, and ERRC. Reviewed with commen
Modify existing fire alarm system by replacing (3) addressable fire alarm control panel. No new devices or wiring.
This project is to improve the space around the Sirrine House. The Sirrine House itself will not be affected by this plan set. The scope of this project is to improve the space around the Sirrine House into an Agricultural Entertainment space. This will involve grading, drainage, water services, sewer services, grease trap, 4 prefabricated containers, a bathroom building, a stage, signage, electrical services, wifi, lighting, proposed materials, food truck stalls and ADA parking. Typical parking
Replace existing fire alarm panel with new. Results in CoC.
Addition and/or Alteration