Search Permits
2,919 results · type: commercial
Private Provider Inspections- Private Provider Inspections- Install Kohler 60 KW Diesel generator on a precast concrete pad & line from existing Ng meter
Private Provider Inspections- Private Provider Inspections- Install Kohler 150 KW Diesel generator on a precast concrete pad
INSTALLING D/F ILLUM PYLON SIGN 20FT- SEE SPECS FOR ENGINEERING
INSTALLING - QTY OF 5- FCO WALL SIGNS NON ILLUM.- SEE SPECS FOR ENGINEERING
Removal & Reinstallation of Solar Panels System on Existing Roof
Installation of 3 LED illuminated wall signs, connect to existing electric
Private Provider Plan Review - *PRIVATE PROVIDER FOR PLAN REVIEW* INTERIOR RENOVATION OF A FOOD DISTRIBUTION/STORAGE CENTER INCLUDING RACKING ANCHORING DECKING AND CONVEYOR SYSTEM STEELWORK STRUCTURE
Target Drive-Up expansion including (1) new light pole, pavement restriping, and a new curb ramp
Construction, repair, remodeling, demolition, and excavation work may be conducted between 6:00 a.m. through 8:00 p.m. Monday through Friday. Work outside of this timeframe requires an afterhours permit. Afterhours permits for construction are subject to the following conditions and Building Official approval: 1. The applicant must provide the following information: a. Location of work 810 S. Country Club Dr. Mesa Az 85210 b. Schedule of hours and days May 3nd at 4:00am (start) to
Install of (2) 15,000 gallon USTR. 1 diesel and 1 Product X (future product) Four existing 3+0 dispensers to be removed and replaced with new 3+1 diesel dispensers. Results in CoC.
New detached garages, type V-B construction, 2,584 SF, S-2 occupancy. Special inspections: steel, concrete, masonry, wood, anchors, and fire-resistant penetrations & joints. 400 amp, 3-phase electrical meter. Deferred submittal: fire sprinklers and fire alarms. Ref: PMT24-16677 for Phase I. Ref: PMT25-21729 for Phase II commercial building. Ref: PMT26-02872 for A2L approved code modification. Approved with stipulations. Results in CofO.
Install (4) 120 gallon vertical propane tanks and connect to existing gas line at loading dock area of an existing building. Results in CofC.
Install (2) new ramadas 144 SF each (288 SF total), picnic tables, and bbq grill at stormwater retention area in new townhouse development. Special inspections required: steel construction, concrete construction, fabricated items, and soils. Results in CoC. 1.5" Landscape meter and all ROW permits included under PMT23-10037. No new landscape meter associated with this project.
LESUEUR IMPROVEMENT PLAN CURB AND GUTTER CONSTRUCTION AND REMOVAL, ALL WITHIN PUBLIC RIGHT OF WAY.
New detached garages, type V-B construction, 2,584 SF, S-2 occupancy. Special inspections: steel, concrete, masonry, wood, anchors, and fire-resistant penetrations & joints. 400 amp, 3-phase electrical meter. Deferred submittal: fire sprinklers and fire alarms. Ref: PMT24-16677 for Phase I. Ref: PMT25-21729 for Phase II commercial building. Ref: PMT26-02872 for A2L approved code modification. Approved with stipulations. Results in CofO.
New detached garages, type V-B construction, 2,584 SF, S-2 occupancy. Special inspections: steel, concrete, masonry, wood, anchors, and fire-resistant penetrations & joints. 400 amp, 3-phase electrical meter. Deferred submittal: fire sprinklers and fire alarms. Ref: PMT24-16677 for Phase I. Ref: PMT25-21729 for Phase II commercial building. Ref: PMT26-02872 for A2L approved code modification. Approved with stipulations. Results in CofO.
Plumbing permit to repair existing gas line like for like , to be installed per City of Mesa and Southwest Gas codes and requirements. Gas pressure test required. No plans Required. *****This permit is for emergency gas line repair like for like only, and does not allow any new gas line installations.*****
New detached garages, type V-B construction, 2,584 SF, S-2 occupancy. Special inspections: steel, concrete, masonry, wood, anchors, and fire-resistant penetrations & joints. 400 amp, 3-phase electrical meter. Deferred submittal: fire sprinklers and fire alarms. Ref: PMT24-16677 for Phase I. Ref: PMT25-21729 for Phase II commercial building. Ref: PMT26-02872 for A2L approved code modification. Approved with stipulations. Results in CofO.
New detached garages, type V-B construction, 2,584 SF, S-2 occupancy. Special inspections: steel, concrete, masonry, wood, anchors, and fire-resistant penetrations & joints. 400 amp, 3-phase electrical meter. Deferred submittal: fire sprinklers and fire alarms. Ref: PMT24-16677 for Phase I. Ref: PMT25-21729 for Phase II commercial building. Ref: PMT26-02872 for A2L approved code modification. Approved with stipulations. Results in CofO.
15 x 30 lunch tent with electric related to FTP26-06231. Tent will be onsite for 12 months and at that time will be removed from the site.
New pool, spa, cold plunge, and pool fencing. New structural, electrical, plumbing, and pool related equipment. Results in CoC.
Addition and/or Alteration
New Construction
Addition and/or Alteration
Addition and/or Alteration
New Construction
Addition and/or Alteration
Addition and/or Alteration
Addition and/or Alteration
Addition and/or Alteration