The apartment complex has 13 buildings with 36 units total. . New water, landscape and electrical meters. Includes a pool and ramada, new drive, parking and retention area. Deferred fire sprinklers and electric vehicle gates.
New EV charger and associated electrical equipment with 2 new parking stalls (1 ADA) at existing gas station. New 400A 3 phase electrical meter. Installation of landscape shrubs in front of new transformer. Results in CoC.
City of Mesa zoning clearance permit only for installation of 16-ft x 68-ft, 2022 above ground set Clayton MH (serial no. 54518). No gas. One (1) detached 10-ft x 40-ft awning, engineering provided by Carl Putnam no. 39702 expires 9/30/24. No other accessory structures under this permit. Minimum two (2) 9-ft x 18-ft paved (2-in asphalt or 4-in concrete) unobstructed parking spaces are required behind front setback one (1) parking space required to be covered. 50-ft x 90-ft interior lot. Minimum
CONSTRUCT A 540 SF SWIMMING POOL NO SPA/NO HEAT. ALL ELECTRICAL TO COMPLY WITH 2017 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: JESSE LIGHT #58912, EXPIRES 12/31/26. ENGINEERING AND STRUCTURAL CALCS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. "THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2018 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF MESA AMENDMENTS".
(4) new padel ball courts with corresponding enclosures, prefabricated container office, and prefabricated handicap restroom. Type V-B construction and group A-5 occupancy, 15,497 SF. New electrical meter and 1 inch water meter. Code Modification PMT25-19333. Special Inspection for concrete construction. Results in CoO.
PERMIT IS ONLY FOR UPGRADE TO A 225A SERVICE AND INSTALLATION OF ONE TESLA POWERWALL 3. B.E.S.S. SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70 PER R327.4. ALL WORK TO BE PERFORMED PER 2018 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF
NEW 2936 SF TWO STORY RESIDENCE WITH 2+ CAR GARAGE FOR TAPESTRY AT DESTINATION. INCLUDES GAS, WATER AND ELECTRIC METERS. SPECIAL INSPECTION FOR POST TENSIONS SLABS. SEE MST23-00515 FOR CHANGES AND PATIO OPTION: MST23-03102 ADDENDA TO 1. REVISED NEW STANDARD PATIO DOOR CONFIGURATION TO BE A 12080 OXXO: 2. REVISED TO ADD OPTIONAL 12080 MULTI SLIDE STACKING (OPTION 026080): 3. REVISED TO ADD OPTIONAL 12080 MULTI SLIDE POCKETING (OPTION 026085)
Remove existing equipment and replace with new on existing cell tower site. Modification to mount required per engineer's report. Must comply with all stipulations listed on the approval administrative letter ADM25-00745. Must provide copy for inspector on site. Results in CoC.
Remodel at existing type 1A, group A2 occupancy restaurant to add a 23ft x 27ft equipment platform with 6ft x 7ft HM door above existing loading dock area for mechanical equipment. Scope to include architectural and structural construction. Deferred fire sprinklers and fire alarms. Special inspection req. - Steel, Masonry, EIFS. Approved with stipulations. Results in CoC.
Third-Floor Elevator Lobby and Corridor demo and remodel, mechanical, electrical, and finishes. No structural or plumbing. Deferred fire sprinklers, fire alarm and access control. Results in CoC.
BLANDFORD HOMES #4502 - MONTELUNA New 2597 SF single story residence with 2+ car garage (tandem). Many porch options. new electric, gas and water meters. special inspection for post tension slabs. See MST21-13101 for Reserve at Red Rock. See MST22-16794 AND MST23-14544 for structural changes at the Grove at Lehi. See MST23-09266 for Montelluna. Site specific structural plans for Grove at Lehi subdivision. Product approval Grove at Lehi ADM21-01107. - EV Capable. ADDENDA MST25-06770 GROVE AT LE
Update plans to the 2018 IRC. New Residential Single story detached 2462 SF with 3 car garage. New water, gas, and electric meter. Post-Tension slab ( Special Inspection). See MST21-06760 for Monteluna. SEE MST21-12324 FOR STRUCTURAL CHANGES AT THE RESERVE AT RED ROCK. SEE MST22-16761 FOR STRUCTURAL CHANGES AT THE GROVE AT LEHI. ADDENDA MST25-06773 GROVE AT LEHI ONLY - CHANGE FROM NATURAL GAS TO PROPANE ON THE PLUMBING SHEET FOR STOVE TOP.
NEW 2129 SF SINGLE STORY RESIDENCE WITH A TWO CAR GARAGE AND STORAGE ROOM FOR TAPESTRY AT DESTINATION. INCLUDES ELECTRIC, GAS AND WATER METERS. SPECIAL INSPECTION FOR POST TENSION SLABS. SEE MST22-09300 EXPAND STORAGE WIDTH 2' TO PROVIDE TURN IN TO SINGLE CAR BAY. ADDENDA MST23-01917 1.REVISED NEW STANDARD CONFIGURATION TO BE 8080 SDG: 2. REVISED TO ADD OPTIONAL 9080 MULTI SLIDE 3. REVISED TO ADD OPTIONAL 9080 MULTI POCKETING DOOR
Sliding Glass Door Removal sliding glass door on back of the house leading outside to to a small staircase that goes to ground level of back yard. Removal of the sliding glass door, building a block wall on lower half of the opening and installing a window in upper half of the opening to match other two windows in the room. Back filling in the area from the home to the stairs. Special inspection for post-installed anchors (epoxy).
Lennar #2016-New 1744 SF two story residence with a 2 car garage for Hawes Crossing - Village 1. Includes a side yard covered patio and a garage with alley access. Special inspection for post tension slabs. Structural Plan Sheets updated to reference Village 1 Phase 2. S-2 & S-2.1: Stair Detail 3A corrected to SD-2 - Floor Truss Schedule for Plan 2, Elev. C updated to show FIDT. S-3: Rear wall detail callouts added for Plan 1, Elev. A. SD-1: Foundation chart note revised to specify -Village 1-ne
TAYLOR MORRISON #3527 -LA MIRA - New 1960 SF single story residence with a two car garage. wrap around porch at corner lots. new meters.
INSTALLATION OF A 60 AMP DEDICATED CIRCUIT BREAKER FOR A WALL CONNECTOR VEHICLE CHARGER IN THE GARAGE. EXISTING 200 AMP SERVICE METER. ELECTRICAL SHALL BE INSTALLED PER MANUFACTURES SPECIFICATIONS AND COMPLY WITH 2018 IBC, 2017 NEC AND SRP STANDARDS. EFFECTIVE JANUARY 8, 2026, THE CITY OF MESA ADOPTED 2024 ICC AND 2023 NEC. AN APPROVED CODE MODIFICATION WAS ADDED TO THIS PERMIT ALLOWING CONTINUED COMPLIANCE WITH 2018 ICC AND 2017 NEC. STARTING APRIL 8, 2026, ALL NEW PERMITTED PROJECTS NOT SPECI
PERMIT IS ONLY FOR INSTALLATION OF ONE TESLA POWERWALL3 BATTERY. ALL WORK TO BE PERFORMED PER 2018 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEES AN