Search Permits
202,811 results
building
building
building
building
building
SELF-CERT 2019 CBC: FULL BUILDING PERMIT FOR 2 STORY 2 D.U. BUILDING WITH BASEMENT, REAR DECK WITH STAIR AT 1ST/2ND STORY, ROOFTOP DECK, ROOFTOP STAIR ENCLOSURE, DETACHED 2 CAR GARAGE AS PER PLAN (OCCUPANCY GROUP R-5, TYPE VA CONSTRUCTION).
SPR 2019 CBRC: INTERIOR RENOVATIONS TO AN EXISTING OFFICE SPACE TO CONVERT TO A ALL DAY MONTESSORI DAY CARE WITHIN AN EXISTING SINGLE STORY BUILDING WORK TO INCLUDE DEMOLITION, NEW PARTITIONS, DOORS AND HARDWARE, LIGHTING, MECHANICAL, ELECTRICAL, AND PLUMBING WORK. NO STRUCTURAL WORK. (CONSTRUCTION TYPE: III-A; OCCUPANCY: E-1 DAY CARE) AS PER PLANS **CERTIFIED PLANS CORRECTIONS: CONDITIONAL PERMIT SUBJECT TO FIELD INSPECTIONS **
REINSTATE PERMIT NO 101037007 MUST BEGIN WORK AND OR REQUEST INSPECTION NO LATER THAN ***OCTOBER 2026*** ON PERMIT NO 101037007
SPR 2019 CBRC. RENOVATION/ REBUILD EXISTING DAMAGED FRONT ENTRY CONCRETE STAIRS AND RETAINING WALL. ALL WORK AS PER PLANS.
LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 100 AMP SERVICE DISCONNECTING MEANS WITH 19 CIRCUITS. RECEPTACLE OUTLETS: 19 . LIGHTING OUTLETS: 0. 13.5 KWH LITHIUM ION ENERGY STORAGE SYSTEM. SPECIFIC LOCATION: GANG METERS.
REMOVE AND REPLACE EXISTING REAR OPEN WOOD PORCH AND STAIRS PER PLANS
INTERIOR REHAB + REPLACEMENT OF EXISTING ENCLOSED & OPEN REAR WOOD PORCHES (SAME SIZE SAME, CONFIGURATION) TO EXISTING, 2 DU, 2 STORY + BASEMENT MASONRY BUILDING(OCCUPANCY GROUP R-2, TYPE 3A CONSTRUCTION)
SELF CERT 2019 CBC: INTERIOR ALTERATIONS TO EXISTING ONE STORY SINGLE FAMILY WITH BASEMENT/ REPLACE FURNACE/ WATER HEATER, PLUMBING FIXTURES, KITCHEN FIXTURES AND DRYWALL REPLACEMENT ONLY/ I-A CONSTRUCTION
TEMPORARY SCAFFOLDING: QTY: 1, MAX. LENGTH: 20 FT., MAX. HEIGHT: 140 FT. LOCATION: WEST AND SOUTH. PERMIT EXPIRATION DATE: 365 DAYS FROM PERMIT ISSUED DATE
LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 200 AMP SERVICE DISCONNECTING MEANS WITH 30 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 1. SPECIFIC LOCATION: BASEMENT, EXTERIOR.
SCOPE: ROOF REPLACEMENT. AREA: 2200 SQ. FT. ROOF COVERING: BUILT-UP ROOF. LOCATION: MODIFIED BITUMEN ROOF REPLACEMENT. IL ROOFING CONTRACTOR LICENSE: 104018955.
INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 10 KW. ARRAY OUTPUT: 10.66 KW. INCLUDES 15 KWH ENERGY STORAGE SYSTEM. LOCATION: ROOF PLANES OF HOME. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.
IN-KIND REPLACEMENT OF EXTERIOR WINDOWS AND DOORS IN EXISTING OPENINGS. REPLACEMENT WINDOWS: 6; REPLACEMENT SKYLIGHTS: 0; REPLACEMENT DOORS: 0. AFFECTS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), LOCATION: FRONT FACADE.
TUCKPOINTING AND UNIT MASONRY REPAIR / REPLACEMENT: 500 SQ. FT., LINTEL QTY. 0, MAX. LENGTH 0. LOCATION: EAST AND SOUTH ELEVATION.
TUCKPOINTING AND UNIT MASONRY REPAIR / REPLACEMENT: 150 SQ. FT., LINTEL QTY. 0, MAX. LENGTH 0. PARAPET REBUILDING: 108 SQ. FT. LOCATION: SOUTH AND EAST ELEVATION.
FINAL REINSTATEMENT ON PERMIT NO 100770526 MUST BEGIN WORK AND OR REQUEST INSPECTION NO LATER THAN ***OCTOBER 2026*** IF INSPECTIONS ARE NOT REQUEST PERMIT WILL CLOSE PERMANENTLY. SEPARATE ADMIN CHANGE REQUIRE TO UPDATE GENCON
SELF-CERT 2019 CBRC: NEW FRONT AND REAR WOOD STAIRS FOR EXISTING 2-STORY, TYPE IIIA MASONRY, 26' HT., 2-UNIT BUILDING WITH ATTIC (NO INTERIOR WORK) (OCCUPANCY GROUP R-5; TYPE IIIA CONSTRUCTION).
REPAIR OR IN-KIND REPLACEMENT OF 2 PLUMBING FIXTURES AS DESCRIBED IN PERMIT APPLICATION. INCLUDES REPAIR OR REPLACMENT OF PLUMBING PIPING. LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), 3 INTERIOR COMMON AREAS, UNIT 8C.
LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 200 AMP SERVICE DISCONNECTING MEANS WITH 28 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 0. SPECIFIC LOCATION: BACK OF THE HOUSE SERVICE UPDATE.
PURPOSE: NEW/REPLACEMENT INSTALLATION. WOOD FENCE - 6'-0' ' (HEIGHT) X 48'-0' ' (LENGTH). LOCATION: REAR YARD, SOUTH SIDE OF THE PROPERTY.
NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 22'-0' ' X20'-0' '. GABLE ROOF HEIGHT TO PEAK: 13'-0' '.
DUCTWORK EXTENSION/RECONFIGURATION, HYDRONIC PIPING EXTENSION/RECONFIGURATION, GAS PIPING EXTENSION/RECONFIGURATION, REPAIR/REPLACEMENT AFFECTING 3 SYSTEMS : 3 BOILER - HOT WATER(WEIL MCLAIN, EVG399, MECHANICAL ROOM) 1 EXHAUST FAN(COOK, 330QMX-HP, MECHANICAL ROOM) 1 OTHER AIR HANDLING EQUIPMENT(MAINSTREAM, CDP-500-7.5-208, MECHANICAL ROOM) . ELECTRICAL WORK UNDER THIS PERMIT = YES . LOCATIONS: 0 RESIDENTIAL UNIT(S), 1 NON-RESIDENTIAL UNIT(S), MECHANICAL ROOM.
NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 24'-0' ' X24'-0' '. GABLE ROOF HEIGHT TO PEAK: 15'-0' '.
TUCKPOINTING AND UNIT MASONRY REPAIR / REPLACEMENT: 200 SQ. FT., LINTEL QTY. 0, MAX. LENGTH 0. LOCATION: FACE OF PROPERTY.
LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 200 AMP SERVICE DISCONNECTING MEANS WITH 1 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 0. SPECIFIC LOCATION: MAIN PANEL, EXTERIOR.