Search Permits
201,887 results
Exterior and Civil improvements for an existing, construction type II-B construction 16,000 SF B/S-1 occupancy building. Scope includes new driveway access, asphalt parking update, concrete sidewalks, masonry site walls, (2) awnings totaling 96 SF, (1) metal patio awing 133 SF, landscaping along East Falcon Dr, and East Road Runner Dr. The replacement or addition of signs on the site will require the review and approval of a separate permit. Special inspection for steel, soils, and post-install
New Custom Home. Deferred fire sprinklers.
TI for second floor suite building type VB with 1-2 occupancy. New interior walls and doors, and finishes. Less than 10 sprinkler heads being added/relocated. Special inspection for post-installed anchoring, concrete, and welding. Deferred fire sprinklers and fire alarm. Approved as noted. Results in CoC.
SHEA HOMES #5016 - NEW 3505 SF TWO STORY RESIDENCE WITH A 3 CAR GARAGE AT AVALON CROSSING. INCLUES MANY ELEVATION OPTIONS. NEW WATER, ELECTRIC AND GAS METERS. Addenda per MST25-12445. Revised and added sheets for foundation slab depth for phase 2 foundations. SPECIAL INSPECTION FOR POST TENSION SLABS.
TI includes new API sampling room, transfer room and new premanufactured hazardous storage shed. Deferred fire sprinklers, fire alarm, access control, and hazardous material alarm. Special inspection for post-installed anchoring and concrete. Results in CoC.
Remodel custom home. Ref. BLD2016-07238 - 1-remove existing guest bathroom door, north wall Frame in space, sheet rock, tape, texture, paint. Install new 28 inch door in north wall, frame in, place molding, repair floor Move light switch from east wall to north wall inside bathroom. 2- remove door frame of laundry room door, demo 3 1/2 feet non-weight bearing wall. Repair drywall, tape texture paint, repair floor. Move light switch to remainder of wall. 3- frame in and install exterior door wi
Stem Wall Repair per engineering plans. Special Inspection Required for: Stem wall repair.
Installation of high piled storage racks in warehouse area of new building. Special inspections required: post-installed anchors. Results in CoC.
CONSTRUCT A 732 SF SWIMMING POOL NO SPA/NO HEAT. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: ALAN E. MONEY #30895, EXPIRES 12/31/26. REF MST19-00383. ENGINEERING AND STRUCTURAL CALCS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. "THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2024 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF MESA AMENDMENTS".
Install one (1) new monument sign with LED screen message board. New structural and electrical. Results in CofC.
REF - PMT24-16945 for original building plans. This permit includes replacing the planned structurally designed warehouse metal building with a Pre-Engineered Metal Building and various associated architectural and electrical changes. Type III-B. Additional SF (S-1 (56 SF) and A-3 (7 SF)) and occupant load (S-1 (1)) will be captured under this permit. Results in CofO.
INSTALLATION OF A 60 AMP DEDICATED CIRCUIT BREAKER FOR A TESLA WALL CONNECTOR VEHICLE CHARGER IN THE GARAGE. EXISTING 200 AMP SERVICE METER. ELECTRICAL SHALL BE INSTALLED PER MANUFACTURES SPECIFICATIONS AND COMPLY WITH 2024 IBC, 2023 NEC AND SRP STANDARDS.
“Installation of 200 Amp electric service - no plans required. Installation shall comply with City of Mesa codes and servicing electric utility requirements. DO NOT DISCONNECT UTILITY WIRES OR METERS. Schedule disconnect/reconnect with serving utility and obtain utility service requirements specific to your permit.”
Installation of whole house Surge / EMP Protection System. Will hire an electrician to install an EMP Shield whole home Surge / EMP protection device on the Service Panel.
PERMIT IS ONLY FOR INSTALLATION OF ONE TESLA POWERWALL3 BATTERY. ALL WORK TO BE PERFORMED PER 2024 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEES AN
Converting tub to shower, replacing pan, drain, and valves.
Related to COB26-00043 : Please note that before a damage permit is issued an estimate showing the Company doing the work, the subject address, scope of work, materials, and labor from either the contractor or the insurance company will be required. A written scope of work is required to approximate the cost of the permit, verbal estimations shall not be used. This structure is to be restored like for like in compliance with 2017 NEC, 2018 IRC/IBC requirements. Any alterations or changes wil
Plumbing Remodel SFR – Remodel 13 SF existing shower - replace shower pan - drain and valve assemblies - install new glass shower door. Type V construction. R5 occupancy. No deferred items. No special inspections.
Converting tub to shower, replacing pan, drain, and valves.
Installation of new 12-foot wide driveway approach per M-1211 residential driveway entrance detail. As noted in plans, no sidewalks exist on this street, and will not be included with new driveway entrance.
Install one LED illuminated pan channel letter sets and logo to front fascia of suite AMERICAN FAMILY INSURANCE 30 sq. ft. Signs shall be installed per NEC 2023 with UL listed components.
Davidson Stem Wall Repair per engineered plans. Special Inspection required for: Stem wall repair
Installation of 200 Amp electric service - no plans required. Installation shall comply with City of Mesa codes and servicing electric utility requirements. DO NOT DISCONNECT UTILITY WIRES OR METERS. Schedule disconnect/reconnect with serving utility and obtain utility service requirements specific to your permit.
Construct a 338-sf swimming pool & 38-sf spa with natural gas heat. Installation of 120-ft of 1.5-in PE gas line buried 18-in deep with 18-gauge tracer wire from gas meter to 400K BTU pool heater, 10-ft of 3/4-in PE gas line to 75K BTU firepit. All gas lines are to be installed per 2018/24 IFGC & COM gas requirements. COM gas to determine if the meter needs to be upgraded. All electrical to comply with 2017 NEC requirements. This permit does not include any accessory structures. Registered struc
Tub to Shower Conversion in Hall Bathroom - Replace existing wet space with new shower including new valve and prefabricated acrylic walls. No structural changes - will tie into existing piping. No change to overall square footage.
Replace existing 200 amp electric panel with a new 400 amp main service panel in the same location at existing SFR.
One illuminated attached building sign 135 sq ft GIO FURNISHINGS w/square outline around verbiage. Halo lit aluminum reverse pan channel letters. Signs shall be installed per NEC 2023 with UL listed components.
CONSTRUCT A 667 SF SWIMMING POOL & 64 SF SPA WITH NATURAL GAS HEAT. INSTALLATION OF 24-FT OF 1-IN PE GAS LINE BURIED 12-IN DEEP WITH 14 GAUGE TRACER WIRE FROM 500-GAL PROPANE TANK TO 400K BTU POOL HEATER. ALL ELECTRICAL TO COMPLY WITH 2017 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: JESSE LIGHT #58912, EXPIRES 12/31/26. ENGINEERING AND STRUCTURAL CALCS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED.
New 174 SF Freestanding Aluminum Lattice-Roof Shade Structure per engineered plans. Includes electrical improvements.
building