CONSTRUCT A 378 SF SWIMMING POOL NO SPA/NO HEAT. ALL ELECTRICAL TO COMPLY WITH 2017 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: JESSE LIGHT #58912, EXPIRES 12/31/26. REF MST25-00925. ENGINEERING AND STRUCTURAL CALCS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. "THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2018 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF MESA AMENDMENTS".
INSTALLATION OF 11-FT-2IN X 33-FT-5IN 2026 CAVCO PARK MODEL WITH AC AT REAR AND UTILITIES. NO GAS OR LP TANKS. NO AWNING. NO OTHER ACCESSORY STRUCTURES AT THIS TIME. MIN ONE 9-FT X 18-FT UNOBSTRUCTURED PAVED 2-IN ASPHALT OR 4-IN CONCRETE PARKING SPACE REQUIRED BEHIND FRONT SETBACK. 33-FT2-IN X 64-FT1-IN INTERIOR LOT. MIN SETBACKS 4-FT, 5-FT REAR, 0-FT PARK MODEL SIDE, AND 3-FT AWNING/CARPORT SIDE. APPROVED AS NOTED.
Tenant improvement of existing 4,494 SF, type II-B construction, B occupancy vacant suite on 2nd level. Modification include new partitions to create offices, breakroom and conf rooms, flooring, ceilings, millwork and associated MEP. Existing restroom in building common area. Existing RTU. Deferred fire sprinklers and fire alarm. Results in CoO.
Lofts @ Pioneer Crossing Homebuilding LLC master plan two-story triplex, R-5 occupancy, one- & two-facility dwelling. Plan1 livable at 1725 and nonlivable at 564, Plan2 livable at 1770 and nonlivable at 574, Plan3 livable at 2055 and nonlivable at 554. Water service 1 inch with 3/4 or 1-inch meter. 200 amp panel electric service. Deferred truss calcs. Fire sprinklers required: submit as an addenda. Special inspection for post tension, epoxy anchors, and soils grading and drainage. EV charger. R
Lofts @ Pioneer Crossing Homebuilding LLC master plan two-story triplex, R-5 occupancy, one- & two-facility dwelling. Plan1 livable at 1725 and nonlivable at 564, Plan2 livable at 1770 and nonlivable at 574, Plan3 livable at 2055 and nonlivable at 554. Water service 1 inch with 3/4 or 1-inch meter. 200 amp panel electric service. Deferred truss calcs. Fire sprinklers required: submit as an addenda. Special inspection for post tension, epoxy anchors, and soils grading and drainage. EV charger. R
Lofts @ Pioneer Crossing Homebuilding LLC master plan two-story triplex, R-5 occupancy, one- & two-facility dwelling. Plan1 livable at 1725 and nonlivable at 564, Plan2 livable at 1770 and nonlivable at 574, Plan3 livable at 2055 and nonlivable at 554. Water service 1 inch with 3/4 or 1-inch meter. 200 amp panel electric service. Deferred truss calcs. Fire sprinklers required: submit as an addenda. Special inspection for post tension, epoxy anchors, and soils grading and drainage. EV charger. R
Add new sail shade and columns to extend to existing sail shade and columns. Special Inspections Required for soils and cast-in-place foundations. Results in CoC.
Install one LED illuminated pan channel letter sets and logo to south elevation of building MOUNTAINSIDE FITNESS 118 sq. ft. Signs shall be installed per NEC 2023 with UL listed components. Ref BOA26-00041
CITY OF MESA ZONING CLEARANCE PERMIT ONLY FOR INSTALLATION OF 24-FT X 50-FT 2026 ABOVE GROUND CAVCO MANUFACTURED HOME SET, SERIAL NO. CAV110AZ26-23465A/B, WITH AC AT REAR. NO LP TANKS. ONE 11-FT X 47-FT ATTACHED AWNING PER ICC NO. ESR1953. ACCESSORY STRUCTURE ROOF AREAS DO NOT EXCEED THE 100% MH FLOOR AREA. NO OTHER ACCESSORY STRUCTURES AT THIS TIME. MINIMUM OF TWO 9-FT X 18-FT PAVED UNOBSTRUCTED PARKING SPACES ARE REQUIRED BEHIND FRONT SETBACK AND REQUIRED TO BE ON 2-IN ASPHALT OR 4-IN CONCRETE
PERMIT IS ONLY FOR THE INSTALLATION OF ONE TESLA POWERWALL3 BATTERY. ALL WORK TO BE PERFORMED PER 2024 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEE
Install (2) gates and (2) 5-foot pole mounted signs at existing service ramp with guard rails. Results in CofC.
New SFR – 24007 SF livable and 12698 SF non livable. Livable breakdown is 6846 SF main house and 17161 SF at barn. Non-livable breakdown is 1670 SF main garage 1197 SF main mechanical and storage 5091 SF main covered patios 1995 SF barn garage 414 SF barn mechanical and storage 1977 SF barn covered patios and 354 SF pool cabana – new single story single family residence with a 2 story detached livable and non livable barn space and detached pool Cabana - approved BOA24-00051 Special Use Permit t
CONSTRUCT A 441 SF SWIMMING POOL & 66 SF SPA. ALL ELECTRICAL TO COMPLY WITH 2017 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: ALAN E. MONEY #30895, EXPIRES 12/31/26. REF MST19-00383. ENGINEERING AND STRUCTURAL CALCS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. "THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2018 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF MESA AMENDMENTS". EFFE
Request for a minor location adjustment to the West Side Monument sign on Eastmark Parkway. The GC is installing (2) flagpoles near this sign, which requires shifting the monument slightly from its originally approved location. The sign’s new location is approximately 22 feet from the property line and 2’-6” east of the previously approved position. The sign angle and overall dimensions remain unchanged. Updated sign location plan drawings are included to show that the monument continues to comp
CITY OF MESA ZONING CLEARANCE PERMIT ONLY FOR INSTALLATION OF 24-FT X 53-FT 2026 ABOVE GROUND CAVCO MANUFACTURED HOME SET, SERIAL NO. CAV110AZ26-23499A/B, WITH A/C AT REAR. NO LP TANKS. ONE 10.9-FT X 53-FT ATTACHED AWNING PER ICC NO. ESR1953. ACCESSORY STRUCTURE ROOF AREAS DO NOT EXCEED THE 100% MH FLOOR AREA. NO OTHER ACCESSORY STRUCTURES AT THIS TIME. MINIMUM OF TWO 9-FT X 18-FT PAVED UNOBSTRUCTED PARKING SPACES ARE REQUIRED BEHIND FRONT SETBACK AND REQUIRED TO BE ON 2-IN ASPHALT OR 4-IN CONCR
Group U occupancy. Type II-B construction. 324 SF. Occupant load 0. Install new 18-foot by 18-foot steel playground shade canopy with fabric cover at new apartment buildings. Special inspections required: concrete construction and steel construction. Results in CofC.
In an existing type II-B construction, Group S-1 occupancy, fully fire sprinklered warehouse, install 13 bay high-piled steel storage racking system with 30-foot maximum storage heights. Special inspections for epoxy & expansion anchors.