PermitDig
tenant_improvement_(interior_only)Revisions received

APPROXIMATELY 6,626 SF PRINT ROOM AND 743 SF BREAKROOM ADDITION WITH INSTALLATION OF MECHANICAL UNIT. ALSO INCLUDES DEMOLITION OF DEMISING WALL SEPARATING EXSISTING SUITES A AND B AND THE ADDITION OF WALLS FOR AN APPRX. 254 SF SES ROOM, THE DOORS OF WHICH ARE UNDER A SEPARATE AND CONCURRENT SUBMITTAL. Deferred fire sprinklers.

8057 E SEBRING AVE, Mesa, AZ

Permit Details

Permit Number
PMT26-16209
Type
tenant_improvement_(interior_only)
Status
revisions received
Issued Date
October 2, 2026
County
Mesa, AZ
View on county site

Parties

Contractor
Bryan Esparza

About tenant_improvement_(interior_only) Permits in AZ

0

tenant_improvement_(interior_only) permits in AZ

Similar tenant_improvement_(interior_only) Permits

Tenant improvement in existing 1,267 SF, type VB construction, B occupancy suite that was once connected to another suite via a door way. Modification include infilling existing door opening to separate suite, new pony walls with guard to expand existing cookline with existing kitchen equip and existing Type 1 exhaust hood. Scope to include new equip such as fridge, freezer, ice cream display, prep tables and display cases and bench seating with associated elec with new lighting. No plumbing, me

Mesa, AZ · PMT26-09828

Demo windows and portion of CMU wall in existing building. Infill masonry wall. Remove one existing RTU to be reused on future phase and one existing RTU to remain in place. Install new RTU in place of removed existing RTU. Store removed existing RTU on sleepers next to new RTU. Remove identified return and supply air ducts. Install new supply, return, and exhaust air ducts. New plenum above exhaust grille. New water supply lines for 3-comp sink, prep sink and hand wash sink. New waste line for

Mesa, AZ · PMT26-05665

Group B occupancy. Type V-B construction. 1,773 SF. Occupant load 49. Demo existing plumbing fixtures in existing suite. New partition walls to create kitchen area, service area, dining room area, and a second restroom in a new restaurant. New kitchen equipment and plumbing fixtures. New electrical lighting and receptacles. (2) existing mechanical heat pump RTUs. New supply air ducts, return air plenum, exhaust fans, and diffusers. New ventless kitchen hood at the oven. New plumbing waste lines

Mesa, AZ · PMT26-14971

Demo of existing space and previous tenant features, taking suites back to gray shell.

Mesa, AZ · PMT26-15676

INTERIOR NON-STRUCTURAL TENANT IMPROVEMENT OF EXISTING COMMERCIAL SUITE.

Mesa, AZ · PMT26-17745

About tenant_improvement_(interior_only) Permits in Mesa, AZ

What is a tenant_improvement_(interior_only) permit?

A tenant_improvement_(interior_only) permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.

How long does this permit remain valid?

Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.

Where does this data come from?

This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.