Tenant improvement in existing 42,632 SF, type VB construction, B and S1 occupancy suite. Modification include adding (4) RTU to serve warehouse area and associated MEP and Str scope. Special inspection req. for Wood. Deferred fire sprinklers. REF: PMT23-02563 Spec Suite 101. Results in CoC.
7412 E WARNER RD 101, Mesa, AZ
Permit Details
- Permit Number
- PMT26-14694
- Type
- tenant_improvement_(interior_only)
- Status
- fees due
- Issued Date
- September 16, 2026
- County
- Mesa, AZ
Parties
- Contractor
- Melissa Martorano
About tenant_improvement_(interior_only) Permits in AZ
0
tenant_improvement_(interior_only) permits in AZ
Other Permits in Mesa, AZ
New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi
3101 E ELMWOOD ST · PMT25-23465
Onsite and Offsite Improvements for Haven at Hawes. Includes (1) 1-inch Pool Meter, (1) 2-inch Landscape Meter and (1) 1" Landscape Meter. 1-inch Domestic services and BFP for each lot, (1) 200 AMP, and (1) 100 AMP electric meter. Deferred electric vehicle gates. Special inspection for post-installed anchors, concrete, and masonry. Reviewed with comments. Results in CoC.
4065 S HAWES RD · PMT26-06671
Install 8-foot iron fence with (5) manual truck gates and (1) pedestrian gate with free egress around loading dock area of existing building. Results in CofC.
2360 W BROADWAY RD 106 · PMT26-09451
Interior renovation of existing cleanroom includes demolition of existing cleanroom wall panels and operable doors with new processing equipment. New clean room area is a required 1-hour fire-rated control area. Includes Architectural, Mechanical, Electrical and Structural Drawings. Special inspection of steel. Deferred fire sprinklers and fire alarm with gas detection. Reviewed as noted. Results in CoC.
730 E BASELINE RD · PMT25-18131
Install storage rack system in an existing warehouse suite. Special inspections required: post-installed anchors. Results in CofC.
2630 N OGDEN 103 · PMT26-07490
Similar tenant_improvement_(interior_only) Permits
Interior renovation of existing cleanroom includes demolition of existing cleanroom wall panels and operable doors with new processing equipment. New clean room area is a required 1-hour fire-rated control area. Includes Architectural, Mechanical, Electrical and Structural Drawings. Special inspection of steel. Deferred fire sprinklers and fire alarm with gas detection. Reviewed as noted. Results in CoC.
Mesa, AZ · PMT25-18131
Install storage rack system in an existing warehouse suite. Special inspections required: post-installed anchors. Results in CofC.
Mesa, AZ · PMT26-07490
Separate single suite into two individual suites. Demo door and frame at storage room. Demo storefront doors. Sawcut curb for new ADA ramp. Install new storefront doors and hardware. Infill door and install partition walls to create two separate suites. New ADA ramp at new ADA parking spots. Demo portion of supply air duct to separate mechanical systems between new separated suites. New supply air duct connected to existing. New return air duct. New electrical meter 200A 3 phase. New electrical
Mesa, AZ · PMT26-04303
Tenant improvement of approximately 3,945 SF within an existing Group B construction type II-B, office space. Scope includes new interior partitions, restrooms, millwork, finishes, ceilings, lighting, and associated mechanical, plumbing, and electrical modifications to support the new office layout. Deferred fire sprinklers and fire alarm. Access control under separate submittal. Special inspection for welding and steel. Results in CoO.
Mesa, AZ · PMT26-12980
A ± 5,996 SQ. FT. INTERIOR REMODEL WITHIN AN EXISTING WAREHOUSE IN THE FUJIFILM FACILITY. THE SCOPE OF WORK INCLUDES A NEW MEZZANINE TO BE ADDED OVER THE EXISTING FINISH GOODS STORAGE AREA. THE FIRST FLOOR INCLUDES A NEW PROCESS AREA, A NEW MAN DOOR, AND A NEW OVERHEAD DOOR FOR EXISTING FORKLIFT TRAFFIC. THE MEZZANINE WILL CONSIST OF TWO NEW PRIVATE OFFICES, AND AN OPEN OFFICE SPACE, ALONG WITH TWO NEW STAIRWELLS FOR STAFF USE. FIRE PROTECTION WILL BE PROVIDED AS REQUIRED AROUND THE MEZZANINE AN
Mesa, AZ · PMT26-13635
About tenant_improvement_(interior_only) Permits in Mesa, AZ
What is a tenant_improvement_(interior_only) permit?
A tenant_improvement_(interior_only) permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.
How long does this permit remain valid?
Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.
Where does this data come from?
This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.