PermitDig
tenant_improvement_(interior_only)Issued

TI in an existing 47,096 SF construction type III-B building. Existing occupancy is S-1 and B. Scope includes first phase of F-1 manufacturing facility. Welding equipment, machinery, ventilation, mechanical, and electrical for warehouse area. Install new overhead KONE crane system under separate permit PMT26-06576. Occupancy change and CoO will be completed under PMT26-08898. Deferred fire sprinklers. Results in CoC.

7157 E SEAVER AVE, Mesa, AZ

Permit Details

Permit Number
PMT26-08603
Type
tenant_improvement_(interior_only)
Status
issued
Issued Date
June 10, 2026
County
Mesa, AZ
View on county site

Parties

Contractor
Ravin Crosby

About tenant_improvement_(interior_only) Permits in AZ

0

tenant_improvement_(interior_only) permits in AZ

Other Permits in Mesa, AZ

New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi

3101 E ELMWOOD ST · PMT25-23465

DH 224: Install 250' of drywall floor to ceiling (125' on each side) to create cooling equipment gallery. DH 227: Install 500' of drywall floor to ceiling (250' on each side) to create cooling equipment gallery All work to include necessary rough openings for fan wall and chilled water piping. All necessary doors and fire extinguishers indicated in the plans will also be install

8807 E WARNER RD · PMT26-12295

Replace beverage equipment and associated MEP with new. Demo identified equipment, drains, water lines, refrigeration lines, and floor sinks. Remove power back to electrical panel for demolished equipment. Install new equipment, waste lines floor sinks, water lines, beverage lines, power for new equipment. Replace existing RTU glycol chiller condensing unit with new. Results in CofC.

2657 S POWER RD · PMT26-11864

CONSTRUCT A 486 SF SWIMMING POOL NO SPA/NO GAS. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: ALAN E. MONEY #30895, EXPIRES 12/31/26. REF MST26-01206. ENGINEERING AND STRUCTURAL CALCS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. "THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2024 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF MESA AMENDMENTS".

10854 E DOVER ST · PMT26-11950

Interior build-out of an existing construction type II-B, 1,855 SF shell office space. Scope includes new interior partitions, restrooms, flooring, ceilings, lighting, millwork and finishes, with associated mechanical, plumbing and electrical modification. Deferred fire sprinkler and fire alarm. Results in CoO.

2559 N GREENFIELD RD · PMT26-11660

Similar tenant_improvement_(interior_only) Permits

Replace beverage equipment and associated MEP with new. Demo identified equipment, drains, water lines, refrigeration lines, and floor sinks. Remove power back to electrical panel for demolished equipment. Install new equipment, waste lines floor sinks, water lines, beverage lines, power for new equipment. Replace existing RTU glycol chiller condensing unit with new. Results in CofC.

Mesa, AZ · PMT26-11864

Interior build-out of an existing construction type II-B, 1,855 SF shell office space. Scope includes new interior partitions, restrooms, flooring, ceilings, lighting, millwork and finishes, with associated mechanical, plumbing and electrical modification. Deferred fire sprinkler and fire alarm. Results in CoO.

Mesa, AZ · PMT26-11660

Interior renovation of existing cleanroom, includes demolition of existing cleanroom wall panels and operable doors with new processing equipment. Includes Architectural, Mechanical, Electrical and Structural Drawings. Special inspection of steel. Deferred fire sprinklers and fire alarm. Results in CoC.

Mesa, AZ · PMT25-18131

Add an access control card reader and panic hardware to a single exterior door. Results in CofC.

Mesa, AZ · PMT26-08108

Group B occupancy. Type V-B construction. 1,579 SF. Occupant load 24. Existing suite. Demo partition walls, interior door frames, interior doors, and East exit door to adjacent suite. New partition wall, door, and door frame to create ADA compliant restroom. Infill exit door at East demising wall. New architectural and MEP. Deferred fire sprinklers. Results in CofO.

Mesa, AZ · PMT26-04675

About tenant_improvement_(interior_only) Permits in Mesa, AZ

What is a tenant_improvement_(interior_only) permit?

A tenant_improvement_(interior_only) permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.

How long does this permit remain valid?

Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.

Where does this data come from?

This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.