Type V-B construction. Group B occupancy. 2,024 SF. Occupant load 14. Vacant existing suite. New partition walls to create isolated children's counseling areas, offices, breakroom, de-escalation room and ADA compliant restroom. New plumbing fixtures at restroom. New mechanical supply air ducting, return air ducting, supply air diffusers, return air grilles, and exhaust fan to roof. 2-exisitng 2000 CFM packaged RTUs with smoke detectors. New plumbing water line, waste line, and point of use water
2919 S ELLSWORTH RD 113, Mesa, AZ
Permit Details
- Permit Number
- PMT25-22768
- Type
- tenant_improvement_(interior_only)
- Status
- c of o issued
- Issued Date
- June 8, 2026
- County
- Mesa, AZ
Parties
- Contractor
- d. rosas design group
About tenant_improvement_(interior_only) Permits in AZ
0
tenant_improvement_(interior_only) permits in AZ
Other Permits in Mesa, AZ
New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi
3101 E ELMWOOD ST · PMT25-23465
Install one illuminated channel letters, on backer panel, mounted onto existing screen wall XPO 32 Sq Ft. Signs shall be installed per NEC 2023 with UL listed components.
7360 S SOSSAMAN RD · PMT26-10820
New single-story 400 SF livable detached ADU. Type V-B construction. Deferred truss calculations. No special inspections. Minimum required building inspections: Plumbing underground, footing, stem, strap/shear, frame, mechanical rough in, electric rough in, plumbing rough in, insulation, drywall shear, mechanical final, electric final, plumbing final and final.
944 S MACDONALD · PMT26-11504
Install three temp banners 07/17/26-12/19/26
2920 N POWER RD 109 · PMT26-12349
adding a gas line to an existing line. The new gas line with be a 2" PE pipe buried no less than 20" with a tracer wire and will connect to the existing 1.5" PE pipe that feeds the 400k pool heater. the new gas line will feed four 20k btu natural gas torches. Ref. PMT26-09824 for the Pergola I will also be installing a 2" PE pipe that will tie into a nipple coming out of the back of the house and will feed a 60k btu natural gas BBQ, a 65k btu natural gas fire pit, and a 20k btu natural gas tor
3408 E IVYGLEN CIR · PMT26-11529
Similar tenant_improvement_(interior_only) Permits
TI in an existing 47,096 SF construction type III-B building. Existing occupancy is S-1 and B. Scope includes first phase of F-1 manufacturing facility. Welding equipment, machinery, ventilation, mechanical, and electrical for warehouse area. Install new overhead KONE crane system under separate permit PMT26-06576. Occupancy change and CoO will be completed under PMT26-08898. Deferred fire sprinklers. Results in CoC.
Mesa, AZ · PMT26-08603
Interior tenant improvement of an approximately 10,000 SF medical spa within a new gray shell building. Work includes new interior partitions, doors, finishes, millwork, and lighting, along with mechanical, electrical, and plumbing systems required to support the spa and wellness functions. The project will be designed and coordinated with structural and MEP engineering consultants. No exterior modifications approved as part of this permit. Deferred fire sprinklers. Results in CoO.
Mesa, AZ · PMT26-04958
Tenant improvement in exist type VB construction warehouse. Modification to include install of demising wall to separate warehouse to create a 51,938 Sf, group B and F-1 manufacturing suite for Water-based battery Electrolyte and other processes that contribute to overall Battery product. Modifications include install employee restroom facility in warehouse area and associated str mech plumb and elect. Walls provided as recommendation in Hiller report/case study REF: PMT25-12010. Special inspect
Mesa, AZ · PMT26-05579
Occupancy verification and Unpermitted work documentation for an existing 1,082 SF, type VB construction, group B occupancy suite. No change to building occupancy use. Unpermitted work - Walls to separate suite and create office, share same electrical service panel with keybox for access to elec panel as allowed by NEC 240.24(b) and approved by Chris Clark. REF: DOC23-14159 for previous floor plans. REF: PMT24-03374 for casenotes. Results in CoO.
Mesa, AZ · PMT26-03161
Tenant improvement in existing 1.786 SF, type VB construction, B occupancy suite. Modification includes install of new demising wall and noise mitigating wall along north wall of tenant suite. REF: PMT26-12559 Demo permit. Fire sprinklered building. Results in CoC.
Mesa, AZ · PMT26-12137
About tenant_improvement_(interior_only) Permits in Mesa, AZ
What is a tenant_improvement_(interior_only) permit?
A tenant_improvement_(interior_only) permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.
How long does this permit remain valid?
Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.
Where does this data come from?
This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.