Tenant improvement of an existing 6,650 SF commercial building and exterior patio space, the interior addition of 3 restrooms, a stage, and repair/reinforcing/permitting of a previously unpermitted steel storage area attached to the north side of the building. Type III-B construction. Special inspections required for Special Cases and Steel Construction. Change of occupancy from existing Group B occupancy to Groups A-2 and M occupancies. Not equipped with fire sprinklers, none required. Deferred
104 E 1ST AVE, Mesa, AZ
Permit Details
- Permit Number
- PMT25-06189
- Type
- tenant_improvement_(interior_only)
- Status
- c of o issued
- Issued Date
- May 19, 2026
- County
- Mesa, AZ
Parties
- Contractor
- STEFAN KAISER
About tenant_improvement_(interior_only) Permits in AZ
0
tenant_improvement_(interior_only) permits in AZ
Other Permits in Mesa, AZ
New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi
3101 E ELMWOOD ST · PMT25-23465
New single-story custom home and ADU with 7938 SF livable and 2967 SF non-livable area. Livable area consists of 7073 SF main residence and 865 SF detached ADU. Non-livable area consists of a four car garage, covered patios and a covered entry. Type V-B construction. Existing 1 inch water meter. New 600 amp SES. New gas meter and new sewer connection. Deferred fire sprinkler calculations and truss calculations. Special inspections required for structural welding, high strength bolts, concrete co
3829 E HUBER ST · PMT26-10492
Onsite and Offsite Improvements for Haven at Hawes. Includes (1) 1-inch Pool Meter, (1) 2-inch Landscape Meter and (1) 1" Landscape Meter. 1-inch Domestic services and BFP for each lot, (1) 200 AMP, and (1) 100 AMP electric meter. Deferred electric vehicle gates. Special inspection for post-installed anchors, concrete, and masonry. Reviewed with comments. Results in CoC.
4065 S HAWES RD · PMT26-06671
Install of SES and transformer with (4) level 2 vehicle charging and (4) future level 3 vehicle charging, and 8" concrete pad for 560 SF factory -built guard house at east staging lot next to Bldg 4. Permit excludes factory-built buildings. Special inspection require - Elect over 1,000amps, concrete and anchors. REF: PMT26-01846 Bldg 4. Approved with comments. Results in CoC.
7237 E PECOS RD · PMT26-09973
Tenant improvement for existing (2) story 490,782 SF shell space data center, Group B/S-1/S-2 occupancy, Type I-B Construction. Modifications of existing 1st level warehouse into 3 data halls. Special inspection req. - Steel, concrete, soils, deep foundations, spray fire resistance material, fire caulking, Mastic & intumescent coating, smoke control. REF: PMT24-02625 Civil, PMT24-09780 Shell, PMT24-11335 Phase 1. Results in CoO at completion of all phases. Result in TCO. Phasing plan.
3856 S EVERTON TERR · PMT24-19524
Similar tenant_improvement_(interior_only) Permits
Tenant improvement for existing (2) story 490,782 SF shell space data center, Group B/S-1/S-2 occupancy, Type I-B Construction. Modifications of existing 1st level warehouse into 3 data halls. Special inspection req. - Steel, concrete, soils, deep foundations, spray fire resistance material, fire caulking, Mastic & intumescent coating, smoke control. REF: PMT24-02625 Civil, PMT24-09780 Shell, PMT24-11335 Phase 1. Results in CoO at completion of all phases. Result in TCO. Phasing plan.
Mesa, AZ · PMT24-19524
TI in an existing 2,141 SF shell suite, type V-B construction, with M and B occupancy. Scope includes interior walls, restrooms, kiln areas, and storage. 1-hour fire rated demising walls to be maintained. Shell building under PMT25-04233. New electric meter. Deferred fire sprinklers. Reviewed with comments. Results in CoO.
Mesa, AZ · PMT25-23390
New Tenant Improvement. Deferred fire sprinklers and alarms.
Mesa, AZ · PMT26-13188
Tenant improvement in existing 1,308 SF, type VB construction warehouse for a group B, F1 and S1 Creamery manufacturing and storage suite. Modifications include new interior partitions to create an office and manufacturing area and associated MEP. REF: PMT24-08553 Bldg 2 Shell and REF: PMT26-04565 shell updates. No high-piled storage under this permit. Deferred fire sprinklers and dust hazard analysis. Approved as noted. Results in CoO.
Mesa, AZ · PMT26-13607
New retail space for a smoke/vape shop sales (no smoking on premises). This space was previously constructed without permits. The tenant applied for a sign permit (PMT26-06468) and was denied by Alex Sanchez. There is currently no suite number for this space left over from the Dunkin Donuts permitted drawing set from 2002 (PMT22-18879). This set of plans shows the current build out and state of the suite for plan review, permitting and suite number assignment. Deferred fire sprinklers.
Mesa, AZ · PMT26-13845
About tenant_improvement_(interior_only) Permits in Mesa, AZ
What is a tenant_improvement_(interior_only) permit?
A tenant_improvement_(interior_only) permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.
How long does this permit remain valid?
Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.
Where does this data come from?
This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.