The existing swimming pool shell was demolished in accordance with the approved City of Mesa partial pool demolition standards. Following demolition, the excavation was backfilled using engineered structural fill consisting of approved granular soil material free of debris, organics, and oversized materials. Backfill was placed in controlled lifts not exceeding 12 inches in loose thickness and compacted to a minimum of 95% of the maximum dry density as determined by ASTM D1557 (Modified Proctor
1423 N ROWEN, Mesa, AZ
Permit Details
- Permit Number
- PMT26-18880
- Type
- swimming_pool
- Status
- submitted
- Issued Date
- October 18, 2026
- County
- Mesa, AZ
Parties
- Contractor
- DILLARD DAVID
About swimming_pool Permits in AZ
0
swimming_pool permits in AZ
Other Permits in Mesa, AZ
New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi
3101 E ELMWOOD ST · PMT25-23465
COD26-05738 - The former in ground swimming pool was cored at the bottom for drainage, the sidewalls were collapsed, and the pool cavity was filled and compacted with clean fill material. Metal 20x25" 13 feet 6 inches in height. shop has been fully constructed - 50 amp electrical ran to shop - Mini Split AC and 35 amp 220 outlet - 5 electrical receptacles and 2 overhead LED lights installed.
1423 N ROWEN · PMT26-16296
Existing daycare suite. Demo existing partition wall. New partition walls, interior door frame, and interior door. New wall bracing at walls previously added during unpermitted construction. Existing CofO under permit #19450 11/18/1987. Deferred fire sprinklers and fire alarm. Approved as noted. Results in CofC.
2111 S ALMA SCHOOL RD 15 · PMT26-17715
Demo portion of exterior wall and storefront door at an existing warehouse building. Install (2) fast track doors, store front door, and vehicle wash portal. Install electrical meter 3000A 3 phase. New structural, plumbing, and electrical. Special inspection required: electrical, post-installed anchors and concrete. Results in CofC.
7035 E PECOS RD 1091 · PMT26-15915
Encroachment Permit for outdoor dining area. Related to PMT26-14204 for TI and occupancy. Results in CoC.
104 W MAIN ST 101 · PMT26-16046
Similar swimming_pool Permits
CONSTRUCT A 428 SF SWIMMING POOL & 49 SF SPA WITH NATURAL GAS HEAT. INSTALLATION OF 150-FT OF 1.5-IN PE GAS LINE BURIED 18-IN DEEP WITH 18 GAUGE TRACER WIRE FROM GAS METER TO 400K BTU POOL HEATER. ALL GAS LINES TO BE INSTALLED PER 2024 IFGC & COM GAS REQUIREMENTS. COM GAS TO DETERMINE IF METER NEEDS TO BE UPGRADED. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: ALAN E. MONEY #30895, EXPIRES
Mesa, AZ · PMT26-11739
CONSTRUCT A 431 SF SWIMMING POOL & 49 SF SPA. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: JESSE LIGHT #58912, EXPIRES 12/31/26. ENGINEERING AND STRUCTURAL CALCS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. "THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2024 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF MESA AMENDMENTS".
Mesa, AZ · PMT26-15692
CONSTRUCT A 488 SF SWIMMING POOL & 46 SF SPA WITH NATURAL GAS HEAT. INSTALLATION OF 64-FT OF 1.5-IN PE GAS LINE BURIED 18-IN DEEP WITH 14 GAUGE TRACER WIRE FROM GAS METER TO 400K BTU POOL HEATER. ALL GAS LINES TO BE INSTALLED PER 2024 IFGC & COM GAS REQUIREMENTS. COM GAS TO DETERMINE IF METER NEEDS TO BE UPGRADED OR NO SPA/NO HEAT. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: JESSE LIGHT #
Mesa, AZ · PMT26-18547
CONSTRUCT A 660 SF SWIMMING POOL & 70 SF SPA WITH NATURAL GAS HEAT. INSTALLATION OF 30-FT OF 1-IN PE GAS LINE BURIED 18-IN DEEP WITH 14 GAUGE TRACER WIRE FROM GAS METER TO 400K BTU POOL HEATER. ALL GAS LINES TO BE INSTALLED PER 2024 IFGC & S GAS REQUIREMENTS. SW GAS TO DETERMINE IF METER NEEDS TO BE UPGRADED. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: JESSE LIGHT #58912, EXPIRES 12/31/26
Mesa, AZ · PMT26-17081
Swimming Pool with baja
Mesa, AZ · PMT26-18627
About swimming_pool Permits in Mesa, AZ
What is a swimming_pool permit?
A swimming_pool permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.
How long does this permit remain valid?
Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.
Where does this data come from?
This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.