16x28 Pool w/ SP and electric line for 400K BTU heater
5155 E DALLAS ST, Mesa, AZ
Permit Details
- Permit Number
- PMT26-15966
- Type
- swimming_pool
- Status
- in review
- Issued Date
- September 15, 2026
- County
- Mesa, AZ
Parties
- Contractor
- MIGUEL BARRON
About swimming_pool Permits in AZ
0
swimming_pool permits in AZ
Other Permits in Mesa, AZ
New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi
3101 E ELMWOOD ST · PMT25-23465
Onsite and Offsite Improvements for Haven at Hawes. Includes (1) 1-inch Pool Meter, (1) 2-inch Landscape Meter and (1) 1" Landscape Meter. 1-inch Domestic services and BFP for each lot, (1) 200 AMP, and (1) 100 AMP electric meter. Deferred electric vehicle gates. Special inspection for post-installed anchors, concrete, and masonry. Reviewed with comments. Results in CoC.
4065 S HAWES RD · PMT26-06671
Install 8-foot iron fence with (5) manual truck gates and (1) pedestrian gate with free egress around loading dock area of existing building. Results in CofC.
2360 W BROADWAY RD 106 · PMT26-09451
Interior renovation of existing cleanroom includes demolition of existing cleanroom wall panels and operable doors with new processing equipment. New clean room area is a required 1-hour fire-rated control area. Includes Architectural, Mechanical, Electrical and Structural Drawings. Special inspection of steel. Deferred fire sprinklers and fire alarm with gas detection. Reviewed as noted. Results in CoC.
730 E BASELINE RD · PMT25-18131
Install storage rack system in an existing warehouse suite. Special inspections required: post-installed anchors. Results in CofC.
2630 N OGDEN 103 · PMT26-07490
Similar swimming_pool Permits
Swimming pool only build: Excavate, rebar, plumbing, shotcrete, masonry, swimming pool equipment set and Swimming pool interior finish per plan.
Mesa, AZ · PMT26-15483
CONSTRUCT A 220-SF SWIMMING POOL. NO SPA. NO GAS. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: ALAN E. MONEY NO. 30895, EXPIRES 12-31-26. REF MST26-01206. ENGINEERING AND STRUCTURAL CALCULATIONS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2024 INTERNATIONAL SWIMMING POOL AND SPA CODE WITH ALL CITY OF MESA AMEND
Mesa, AZ · PMT26-16217
IN GROUND POOL WITH EQUIPMENT, ELECTRIC HEAT PUMP, SUNKEN BAR WITH GFCI WEATHER PROTECTED OUTLET, 125K BTU FIRE FEATURE, & GAS LINE
Mesa, AZ · PMT26-16791
CONSTRUCT A 645 SF SWIMMING POOL & 56 SF SPA WITH NATURAL GAS HEAT. INSTALLATION OF 65-FT OF 2-IN PE GAS LINE BURIED 18-IN DEEP WITH 14 GAUGE TRACER WIRE FROM GAS METER TO 400K BTU POOL HEATER WITH EXISTING RAMADA, SLIDE, AND GROTTO. ALL GAS LINES TO BE INSTALLED PER 2024 IFGC & SW GAS REQUIREMENTS. SW GAS TO DETERMINE IF METER NEEDS TO BE UPGRADED. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGIN
Mesa, AZ · PMT26-14714
CONSTRUCT A 338-SF SWIMMING POOL AND A 49-SF SPA WITH NATURAL GAS HEAT. INSTALLATION OF 61-FT OF 2-IN PE GAS LINE BURIED 18-IN DEEP WITH 18-GAUGE TRACER WIRE FROM GAS METER TO TEE, 3-FT FROM TEE TO 65K BTU BBQ STUB, 72-FT OF 2-IN PE GAS LINE FROM TEE TO 400K BTU POOL HEATER. ALL GAS LINES ARE TO BE INSTALLED PER 2024 IFGC AND SW GAS REQUIREMENTS. SW GAS TO DETERMINE IF THE METER NEEDS TO BE UPGRADED. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY
Mesa, AZ · PMT26-15877
About swimming_pool Permits in Mesa, AZ
What is a swimming_pool permit?
A swimming_pool permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.
How long does this permit remain valid?
Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.
Where does this data come from?
This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.