CONSTRUCT A 431 SF SWIMMING POOL & 63 SF SPA WITH NATURAL GAS HEAT. INSTALLATION OF 150-FT OF 2-INCH PE GAS LINE BURIED 18-INCH DEEP WITH 18 GAUGE TRACER WIRE FROM GAS METER TO 400K BTU POOL HEATER. ALL GAS LINES TO BE INSTALLED PER 2018 IFGC & COM GAS REQUIREMENTS. COM GAS TO DETERMINE IF METER NEEDS TO BE UPGRADED. ALL ELECTRICAL TO COMPLY WITH 2017 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: ALAN E. MONEY #30895, EXPIRE
5756 E SANFORD ST, Mesa, AZ
Permit Details
- Permit Number
- PMT25-11003
- Type
- swimming_pool
- Status
- c of c issued
- Issued Date
- June 8, 2026
- County
- Mesa, AZ
Parties
- Contractor
- Rylee Ellsworth
About swimming_pool Permits in AZ
0
swimming_pool permits in AZ
Other Permits in Mesa, AZ
New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi
3101 E ELMWOOD ST · PMT25-23465
Install one illuminated channel letters, on backer panel, mounted onto existing screen wall XPO 32 Sq Ft. Signs shall be installed per NEC 2023 with UL listed components.
7360 S SOSSAMAN RD · PMT26-10820
New single-story 400 SF livable detached ADU. Type V-B construction. Deferred truss calculations. No special inspections. Minimum required building inspections: Plumbing underground, footing, stem, strap/shear, frame, mechanical rough in, electric rough in, plumbing rough in, insulation, drywall shear, mechanical final, electric final, plumbing final and final.
944 S MACDONALD · PMT26-11504
Install three temp banners 07/17/26-12/19/26
2920 N POWER RD 109 · PMT26-12349
adding a gas line to an existing line. The new gas line with be a 2" PE pipe buried no less than 20" with a tracer wire and will connect to the existing 1.5" PE pipe that feeds the 400k pool heater. the new gas line will feed four 20k btu natural gas torches. Ref. PMT26-09824 for the Pergola I will also be installing a 2" PE pipe that will tie into a nipple coming out of the back of the house and will feed a 60k btu natural gas BBQ, a 65k btu natural gas fire pit, and a 20k btu natural gas tor
3408 E IVYGLEN CIR · PMT26-11529
Similar swimming_pool Permits
CONSTRUCT A 449 SF SWIMMING POOL & 49 SF SPA WITH NATURAL GAS HEAT. INSTALLATION OF 98-FT OF 1-1/4-IN PE GAS LINE BURIED 18-IN DEEP WITH 14 GAUGE TRACER WIRE FROM GAS METER TO 400K BTU POOL HEATER. ALL GAS LINES TO BE INSTALLED PER 2024 IFGC & COM GAS REQUIREMENTS. COM GAS TO DETERMINE IF METER NEEDS TO BE UPGRADED OR NO SPA/NO HEAT. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: ALAN E. MON
Mesa, AZ · PMT26-10071
CONSTRUCT A 382 SF SWIMMING POOL & 38 SF SPA, POOL HEATER, NO HEAT. ALL ELECTRICAL TO COMPLY WITH 2017 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: RALPH M TAVARES #36352, EXPIRES 06/30/2028. ENGINEERING AND STRUCTURAL CALCS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. "THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2018 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF MESA AMENDMENTS"
Mesa, AZ · PMT25-22153
CONSTRUCT A 570 SF SWIMMING POOL NO SPA/NO GAS. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: JESSE LIGHT #58912, EXPIRES 12/31/26. ENGINEERING AND STRUCTURAL CALCS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. "THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2024 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF MESA AMENDMENTS".
Mesa, AZ · PMT26-13296
CONSTRUCT A 700-SF SWIMMING POOL WITH NATURAL GAS HEAT. NO SPA. INSTALLATION OF 80-FT OF 2-IN PE GAS LINE BURIED 18-IN DEEP WITH 18-GAUGE TRACER WIRE FROM GAS METER TO 400K BTU POOL HEATER, 150-FT OF 1.5-IN PE GAS LINE TO 60K BTU FIRE PIT. ALL GAS LINES ARE TO BE INSTALLED PER 2024 IFGC AND COM GAS REQUIREMENTS. COM GAS TO DETERMINE IF THE METER NEEDS TO BE UPGRADED. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL
Mesa, AZ · PMT26-13629
Desert Uplands Envelope Lot - Construct Swimming Pool & Spa. All work related to swimming pool and spa is within the existing privacy fence and temporary fence. No new disturbance with this permit. The temporary fence is required to remain in place per the approved site plan at all times during construction. All areas out of the approved disturbance area shall remain undisturbed at all times. Property line fencing is not permitted. A separate zoning inspection is required prior to final buildin
Mesa, AZ · PMT26-14988
About swimming_pool Permits in Mesa, AZ
What is a swimming_pool permit?
A swimming_pool permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.
How long does this permit remain valid?
Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.
Where does this data come from?
This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.