REMODEL AND ADDITION TO SINGLE FAMILY RESIDENCE. Truss Calcs deferred. Epoxy anchors special inspections. Inspector to field verify 3000 PSI concrete mix design. REMODEL TO EXISTING DINING AREA. REMOVE PARTIAL EXISTING ROOF FOR ADDITION. REVISE ELECTRICAL AND MECHANICAL SYSTEM THROUGHOUT ADDITION.
1322 N 66TH ST, Mesa, AZ
Permit Details
- Permit Number
- PMT24-14888
- Type
- remodeling_with_addition
- Status
- issued
- Issued Date
- July 8, 2026
- County
- Mesa, AZ
Parties
- Contractor
- Katie Whitaker
About remodeling_with_addition Permits in AZ
0
remodeling_with_addition permits in AZ
Other Permits in Mesa, AZ
New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi
3101 E ELMWOOD ST · PMT25-23465
COB26-00040 Repairs of fire damaged home. No change to overall square footage. Truss calculations deferred. Special inspections required for drill & epoxy. Minimum required building inspections: Framing and final.
301 W 9TH PL N · PMT26-08445
Tub to Shower in Hall Bathroom at existing SFR - Replace existing wet space with new shower including new valve and prefabricated acrylic walls. No structural changes - will tie into existing piping. No change to overall square footage.
2438 E JEROME AVE · PMT26-11437
PERMIT IS ONLY FOR INSTALLATION OF ONE TESLA POWERWALL 3 BATTERY. ALL WORK TO BE PERFORMED PER 2024 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEES
8056 E MADERO AVE · PMT26-11349
Interior renovation of the Macayou's restaurant at the AZA Airport into a Cold Beer and Cheeseburgers. The work requires demo and rebuild of dining area, new bar and new storage room. Deferred fire sprinklers, fire alarm and hood fire suppression.
6033 S SOSSAMAN RD · PMT26-09126
Similar remodeling_with_addition Permits
Adding additional 152 square feet livable to second floor of approved PMT25-23054 for and ADU: relocate approved staircase: remove interior partition wall at mudroom location to combine laundry room and mud room: relocate door. Minimum required building inspections: Footing, stem, strap/shear, frame, insulation, drywall shear and final. If needed, underground electrical and plumbing. All inspection to take place under main permit PMT25-23054
Mesa, AZ · PMT26-11124
Remodel and addition on existing SFR consisting of addition 1,346 SF Livable area, 538 SF covered patio. Remodel 537 SF Livable area and 190 SF covered patio. Special inspections required for: Epoxy/, expansion anchors and steel lintel. Minimum required building inspections: Footing, stem, strap/shear, frame, electrical, insulation, drywall shear. If needed, underground plumbing. Final.
Mesa, AZ · PMT26-11424
Demolished existing rear cover patios, demolished rear exterior stairs, demolished rear upper deck. New 171 S.F. and 116 S.F. rear covered patios, new 73 S.F. storage, new 229 S.F. outdoor kitchen, new 250 S.F. upper floor covered deck. All work is non-livable
Mesa, AZ · PMT26-02624
Residential Remodel SFR – Total of 2641.5 SF remodel. First floor remodel includes 831.5 SF of existing non livable area converted to livable space. Second floor remodel includes 1358 SF converting the existing attic storage to livable space. Non livable addition consists of 48 SF storage and mechanical room. Type V construction. R5 occupancy. Existing 3/4 inch water meter to remain. No change to gas. No upgrade to electrical meter. No deferred items. No special inspections. Residential Inspect
Mesa, AZ · PMT26-07999
COB25-00162 - Convert existing carport and laundry room into an attached ADU, add 683 S.F. livable addition to rear of house and add a 271 S.F. front porch at existing SFR. Minimum required building inspections: Footing, stem, strap/shear, frame, insulation, drywall shear and final. If needed, underground electrical and plumbing.
Mesa, AZ · PMT26-08419
About remodeling_with_addition Permits in Mesa, AZ
What is a remodeling_with_addition permit?
A remodeling_with_addition permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.
How long does this permit remain valid?
Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.
Where does this data come from?
This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.