New 337 SF livable accessory structure and 74 SF non-livable covered deck. Type V-B construction. No upgrade to utilities. No deferred items. No special inspections. Park models are governed by the State of Arizona’s Office of Manufactured Housing (OMH). Any modifications to premanufactured structures shall go through OMH. All construction extending outside premanufactured structures are governed by the City of Mesa. Minimum required inspections: Footing, stem, strap/shear, frame, insulation, dr
233 N VAL VISTA DR 383, Mesa, AZ
Permit Details
- Permit Number
- PMT26-13402
- Type
- park_model_other_addition
- Status
- revisions required
- Issued Date
- September 16, 2026
- County
- Mesa, AZ
Parties
- Contractor
- CAL-AM CONSTRUCTION SERVICES
About park_model_other_addition Permits in AZ
0
park_model_other_addition permits in AZ
Other Permits in Mesa, AZ
New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi
3101 E ELMWOOD ST · PMT25-23465
New data center civil site improvements. Installation of all off-site improvements and street frontage landscaping during the first phase of construction. Water Meters: (1) 2-inch Landscape meter. Deferred vehicle access gates. REF: PMT26-08422 Bldg 2. Approved with comments. Results in CoC.
10437 E ELLIOT RD · PMT26-08422
Interior build-out of an existing construction type II-B, 1,855 SF shell office space. Scope includes new interior partitions, restrooms, flooring, ceilings, lighting, millwork and finishes, with associated mechanical, plumbing and electrical modification. Deferred fire sprinkler and fire alarm. Results in CoO.
2559 N GREENFIELD RD · PMT26-11660
Demo existing kitchen equipment and waste lines at area of work to occur. Demo existing Type I hood, associated ducting, and roof top exhaust fan. New Captive Air Type I kitchen hood exhaust system, fire suppression system, grease duct, and associated equipment. New roof top exhaust fan and grille. Trench for new floor sink tie new waste line into existing grease waste line. New vent from floor sink to ceiling and tie into nearest existing vent through roof. New exhaust fan for relocated combin
5957 E MCDOWELL RD · PMT26-03338
RELATED TO COB26-00035 8382 SF interior remodel of the existing two-story single family residence and existing attached ADU consisting of 5536 SF at the first floor and 2846 SF at the second floor. Existing exterior footprint, roof structure and foundation to remain. Existing 1.5 inch water meter to remain. Existing 400 amp SES with electrical modifications. Separate demolition permit required for demolition work. Type V-B construction. No deferred items. Special inspections required for epoxy a
2549 E FLORIAN CIR · PMT26-07601
Similar park_model_other_addition Permits
Construction of a new 246 SF livable accessory structure, 110 SF attached storage room, 200 SF awning for parking area and 152 SF non-livable covered deck. Type V-B construction. No upgrade to utilities. No deferred items. No special inspections. Awning engineering provided by Carl Putnam, No. 39702, expires 9-30-27. Minimum of one 9-ft x 18-ft unobstructed paved parking space required behind front setback on 2-in asphalt or 4-in concrete. 35-ft x 48-ft interior lot. Minimum setbacks are 3-ft fr
Mesa, AZ · PMT26-13427
ALL INCLUSIVE PERMIT FOR PARK MODEL SET, AWNING AND ADDITION. PARK MODEL SHALL NOT BE OCCUPIED UNTIL ALL STRUCTURES ARE COMPLETE AND FINAL INSPECTION PERFORMED. INSTALLATION OF 12.08-FT X 34.08-FT 2026 CAVCO TUSCANY PARK MODEL SERIAL #CFPUS3440T1211398 WITH A/C IN REAR. NO GAS OR LP TANKS. ONE 9.92-FT X 18-FT AWNING, ENGINEERING PROVIDED BY CARL PUTNAM #39702. CONSTRUCTION OF 310 SQ FT ADDITION WITH BATHROOM AND 80 SQ FT STORAGE UNDER AWNING WITH CEILING JOISTS, ELECTRIC AND PLUMBING FOR BATHR
Mesa, AZ · PMT26-06383
ADDITION. REF. PM SET PMT26-07825
Mesa, AZ · PMT26-13542
New 360 SF accessory structure and 74 SF non-livable covered deck. Type V-B construction. No upgrade to utilities. Permit restricted to work outside park model. Minimum required inspections: Footing, stem, strap/shear, frame, insulation, drywall shear, and final. If needed, underground electrical and plumbing. REF. PM SET PMT22-02287
Mesa, AZ · PMT26-13545
Build new 460 sq ft AZ room and storage area. Wood framed with plumbing and electrical.
Mesa, AZ · PMT26-14727
About park_model_other_addition Permits in Mesa, AZ
What is a park_model_other_addition permit?
A park_model_other_addition permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.