ALL INCLUSIVE PERMIT FOR PARK MODEL SET, AWNING AND ARIZONA ROOM. PARK MODEL SHALL NOT BE OCCUPIED UNTIL ALL STRUCTURES ARE COMPLETE AND FINAL INSPECTION PERFORMED. INSTALLATION OF 15.67-FT X 25.33-FT 2026 CAVCO EL PASO PARK MODEL WITH A 15.67-FT X 10-FT FACTORY DECK/PORCH. A/C IN REAR. INSTALL NEW 13.33-FT X 18-FT AWNING. NO GAS OR LP TANKS. CONSTRUCTION OF 267 SQ FT LIVABLE ADDITION WITH ELECTRIC AND PLUMBING FOR BATHROOM, WASHER/DRYER ON RAISED DECK. ACCESSORY STRUCTURE ROOF AREAS DO NOT EX
1452 S ELLSWORTH RD 1503, Mesa, AZ
Permit Details
- Permit Number
- PMT25-19481
- Type
- park_model_other_addition
- Status
- finaled
- Issued Date
- September 2, 2026
- County
- Mesa, AZ
Parties
- Contractor
- CAL-AM CONSTRUCTION SERVICES
About park_model_other_addition Permits in AZ
0
park_model_other_addition permits in AZ
Other Permits in Mesa, AZ
New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi
3101 E ELMWOOD ST · PMT25-23465
Adding a attached Bath addition
2726 E DOWNING CIR · PMT26-11467
New single-story 400 SF livable detached ADU. Type V-B construction. Deferred truss calculations. No special inspections. Minimum required building inspections: Plumbing underground, footing, stem, strap/shear, frame, mechanical rough in, electric rough in, plumbing rough in, insulation, drywall shear, mechanical final, electric final, plumbing final and final.
944 S MACDONALD · PMT26-11504
Onsite grading, drainage, paving, utilities, landscaping, street lights, structural, and site electrical. Scope includes base of new monument sign for water feature and shade structure. Special inspection for steel, concrete, masonry, and soils. New (1) 2-inch landscape meter, (1) 3/4-inch water feature meter, (2) electric meters, and (1) gas meter. Deferred electric vehicle gate. Results in CoC.
Unknown · PMT26-10520
Installation of storage racks scope area of 191,364 SF in existing 353,600 SF, type VB construction, B and S-1 occupancy cold storage warehouse. Special inspection req for anchoring. REF: PMT24-10017 PH I and PMT24-11533 PH II. Results in CoC.
8959 E WARNER RD · PMT26-07672
Similar park_model_other_addition Permits
Construction of 271 sq ft addition with electric and plumbing for bathroom, washer and dryer on raised deck. New 61 sq ft exterior covered deck, 13 sq ft shed and new 162 sq ft covered parking. Awning engineering provided by Carl Putnam no. 39702, expires 9-30-27. Interior lot. Minimum setbacks are 7-ft front, 5-ft rear, 3-ft sides. One 9-ft x 18-ft paved unobstructed parking required behind front setback on 2-in asphalt or 4-in concrete. No other accessory structures at this time. Accessory str
Mesa, AZ · PMT26-11589
CONSTRUCTION OF 347 SQ FT LIVABLE ADDITION AND 120 SQ FT SHED UNDER EXISTING AWNING WITH CEILING JOISTS, ELECTRIC AND PLUMBING FOR LAUNDRY ROOM AND BATHROOM AND A 100 SQ FT UNCOVERED DECK. THE EXISTING AWNING IS CONSIDERED A LEGAL NONCONFORMING STRUCTURE PER MZO SECTION 11-36-4 AS IT EXCEEDS THE MAXIMUM SQUARE FOOTAGE ALLOWED PER MZO SECTION 11-34-2. THE STRUCTURE MAY REMAIN PROVIDED THAT NO EXPANSIONS OR ENLARGEMENTS ARE MADE, AND THE STRUCTURE IS NOT REMOVED OR DEMOLISHED. MINIMUM OF ONE 9-FT
Mesa, AZ · PMT26-05400
New 337 SF livable accessory structure and 74 SF non-livable covered deck. Type V-B construction. No upgrade to utilities. No deferred items. No special inspections. Park models are governed by the State of Arizona’s Office of Manufactured Housing (OMH). Any modifications to premanufactured structures shall go through OMH. All construction extending outside premanufactured structures are governed by the City of Mesa. Minimum required inspections: Footing, stem, strap/shear, frame, insulation, dr
Mesa, AZ · PMT26-13402
ADDITION SL M-21. REF. PM SET PMT26-08774
Mesa, AZ · PMT26-15081
Adding an addition/new kitchen to existing park model. Attaching all the stamped sealed structural engineering which refers to both the park model and the new addition. Remodel Park Model. Minimum required building inspections: Footing, stem, strap/shear, frame, insulation, drywall shear and final. If needed, underground electrical and plumbing.
Mesa, AZ · PMT26-15358
About park_model_other_addition Permits in Mesa, AZ
What is a park_model_other_addition permit?
A park_model_other_addition permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.
How long does this permit remain valid?
Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.
Where does this data come from?
This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.