Engineered repair of (5) damaged joists in suite H. Special inspection for repair observations, welding, wood framing. Results in CoC.
320 E 10TH DR H, Mesa, AZ
Permit Details
- Permit Number
- PMT26-10763
- Type
- other_commercial
- Status
- c of c issued
- Issued Date
- September 23, 2026
- County
- Mesa, AZ
Parties
- Contractor
- Melissa Gillow
About other_commercial Permits in AZ
0
other_commercial permits in AZ
Other Permits in Mesa, AZ
New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi
3101 E ELMWOOD ST · PMT25-23465
Install (5) new HVAC RTUs at existing building for the warehouse area and associated electrical. Special Inspections Required: Wood construction. Deferred fire sprinklers. Approved as Noted. Results in CofC
4228 S SOSSAMAN RD · PMT26-12356
CONSTRUCT A 351 SF SWIMMING POOL NO SPA/NO GAS. ALL ELECTRICAL TO COMPLY WITH 2023 NEC REQUIREMENTS. THIS PERMIT DOES NOT INCLUDE ANY ACCESSORY STRUCTURES. REGISTERED STRUCTURAL PROFESSIONAL ENGINEER: ALAN E. MONEY #30895, EXPIRES 12/31/26. REF MST26-01206. ENGINEERING AND STRUCTURAL CALCS ARE REQUIRED TO BE ONSITE FOR ALL INSPECTIONS AND OPTIONS HIGHLIGHTED. "THESE PLANS MUST CONFORM TO THE REQUIREMENTS OF THE 2024 INTERNATIONAL SWIMMING POOL & SPA CODE WITH ALL CITY OF MESA AMENDMENTS".
10214 E THATCHER AVE · PMT26-11951
Development of new 25,619 SF, type VB construction, group B and S1 occupancy office bldg. Scope to include interior fit out, mechanical, plumbing and electrical. Special inspection req. for Concrete, masonry, steel, post install anchors, soils. Special inspection req. Elec equip rated 1000A. Deferred Wood truss. Water Meter: (1) 1-1/2 inch Domestic meter and 2-inch service. Deferred fire sprinklers and fire alarm. REF: PMT26-10001 for Civil Landscape. Results in CoO.
5118 S 71ST ST · PMT26-08579
Development of new 6,053 SF, type V-B construction, M occupancy shell bldg with 1,291 SF Canopy. Special inspection for steel, masonry, and electrical equip 1000A and up. Deferred Wood Truss. Deferred fire sprinklers. Water Meter: (1) 1-1/2 inch Domestic meter and service. REF: PMT26-12926 Civil and PMT25-11661 Eastmark Site. Results in CoC.
9257 E SERENITY AVE · PMT26-11817
Similar other_commercial Permits
** Big Set** BHSM is seeking to do an approximant 13,000 SF single-story building expansion to add 20-patient rooms and ancillary support spaces to their existing inpatient rehabilitation hospital located in Mesa, AZ. Disciplines included are civil, landscape, structural, architecture, MEPF, and technology.
Mesa, AZ · PMT26-10466
Addition of two dog park cells at existing dog park area in City of Mesa park. Install new water fountain and tie water line to existing water fountain supply line. Install new sight lighting and tie into existing electrical meter. Install new chain link fencing and gates. Install (2) 2-inch landscape water services and (2) 2-inch water meters. Results in CofC.
Mesa, AZ · PMT26-10682
UNAUTHORIZED CONSTRUCTION. COB26-00053 - Create a maintenance storage shed in rear of property. Size approx. 288 sq ft 12x24
Mesa, AZ · PMT26-04822
Interior alterations to existing Buildings 1, 4, and 5, including remodel of the existing café in Building 1, interior renovations to Buildings 4 and 5, a 24-sf addition to Building 5, and new steel entry canopies at Buildings 4 and 5 totaling 631 sf. Type V-B construction, A-3 occupancy. Building 5 interior separation wall 2-hour fire-resistance-rated assembly to remain, new code required 1-hour corridor in building 5 North. New grease interceptor. Deferred fire alarm. Special inspection requir
Mesa, AZ · PMT26-13047
Temporary construction power installation consisting of one 100 kW/125 kVA, 208Y/120V, 3-phase generator supplying a 400A temporary distribution panel, temporary power distribution equipment, two 12-ton A/C units, and associated fire alarm power. Installation includes temporary SOOW feeder cables, grounding and bonding, and associated connections. Temporary installation is limited to 180 days or less. Fire permit FTP26-12869 and alarm PMT26-13549. Results in CoC.
Mesa, AZ · PMT26-13551
About other_commercial Permits in Mesa, AZ
What is a other_commercial permit?
A other_commercial permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.
How long does this permit remain valid?
Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.
Where does this data come from?
This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.