Demo of existing adjacent 2,500 SF building on site. Remodel of existing 2,470 SF and addition of 2,618 SF of type VB construction, group M occupancy dispensary to include site work. Adjacent suite #38 to be shell space. New plumbing for (1) ADA restroom, (1) standard restroom, mechanical (3) new RTUs and ductwork, new elect meter at exist 600a SES with E-Mon D-Mon meter. Special inspection req. - steel, concrete, masonry, epoxy/expansion anchors. Deferred fire sprinklers. Approved as noted. Res
330 E SOUTHERN AVE, Mesa, AZ
Permit Details
- Permit Number
- PMT26-02621
- Type
- other_commercial
- Status
- revisions received
- Issued Date
- July 10, 2026
- County
- Mesa, AZ
Parties
- Contractor
- Kevin Kerpan
About other_commercial Permits in AZ
0
other_commercial permits in AZ
Other Permits in Mesa, AZ
New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi
3101 E ELMWOOD ST · PMT25-23465
Build 572 SF detached ADU with architectural, and MEP. Meter
1622 W DALE CIR 101 · PMT26-08105
Scope of Work includes review for foundation inspections, structural steel package review, electrical package review and any special inspections for a privately owned substation. Special Inspections are required for concrete, soils, steel, and electrical installations. New typical substation prefabricated metal equipment enclosure, shipped to site in one piece.
7232 E ELLIOT RD · PMT26-08686
ADD TWO NEW DEDICATED CIRCUITS 20 AMPS FOR THE BBQ & PERGOLA IN THE BACK. WE WILL RUN UNDER GROUND CONDUIT. 3/4 PVC SCHEDULE 40 PIPE
10555 E THORNTON AVE · PMT26-12726
PERMIT IS ONLY FOR THE INSTALLATION OF ONE TESLA POWERWALL3 BATTERY. ALL WORK TO BE PERFORMED PER 2024 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEE
1846 S 24TH ST · PMT26-11076
Similar other_commercial Permits
Scope of Work includes review for foundation inspections, structural steel package review, electrical package review and any special inspections for a privately owned substation. Special Inspections are required for concrete, soils, steel, and electrical installations. New typical substation prefabricated metal equipment enclosure, shipped to site in one piece.
Mesa, AZ · PMT26-08686
Pool accessory building includes (1) men's and (1) women's restroom with breezeway, drinking fountain, an adjacent pool equipment corral, and outdoor shower area. Occupancy classification B, construction type VB. Adjacent pool area, including pool deck, pool, bbq area and pool enclosure comprised of fencing, walls and gates are under separate permit.
Mesa, AZ · PMT20-15844
Asphalt Testing
Mesa, AZ · PMT24-16923
Demo existing gas fired hot water boilers, storage tanks, expansion tanks, hot water supply, recirculation pumps, and gas piping at East and West buildings. Install new electric boilers, hot water piping, expansion tanks, recirculation pumps, and controls at East and West buildings. Results in CofC.
Mesa, AZ · PMT26-10686
Install three new shade structures in exterior break area of an existing building. Total coverage area 2,272 SF. Results in CofC.
Mesa, AZ · PMT26-09980
About other_commercial Permits in Mesa, AZ
What is a other_commercial permit?
A other_commercial permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.
How long does this permit remain valid?
Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.
Where does this data come from?
This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.