PermitDig
new_park_modelFinaled

INSTALLATION OF 11.5-FT X 37-FT 1997 CAVCO PARK MODEL WITH A/C IN REAR. NO GAS OR LP TANKS. ONE 12-FT X 19.42-FT AWNING AND ONE 11-FT X 15.5-FT AWNING. ENGINEERING PROVIDED BY CARL PUTNAM NO. 39702, EXPIRES 9-30-27. ACCESSORY STRUCTURES DO NOT EXCEED 100% OF THE PM FLOOR AREA. ACCESSORY STRUCTURES SHALL BE REMOVED WITHIN 60 DAYS OF REMOVAL OF THE PM. PER SECTION 11-34-2(A) OF THE MESA ZONING ORDINANCE, AMENDED IN JULY 2025. NO OTHER ACCESSORY STRUCTURES AT THIS TIME. MINIMUM ONE 9-FT X 18-FT UNO

3165 E UNIVERSITY DR 314, Mesa, AZ

Permit Details

Permit Number
PMT26-11159
Type
new_park_model
Status
finaled
Issued Date
July 16, 2026
County
Mesa, AZ
View on county site

Parties

Contractor
Orangewood Shadows RV Resort

About new_park_model Permits in AZ

0

new_park_model permits in AZ

Other Permits in Mesa, AZ

New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi

3101 E ELMWOOD ST · PMT25-23465

Tenant improvement in existing 43,540 SF, type III-B construction, A-3 occupancy with 2,978 SF outdoor area for a health and fitness club. Special inspection req. for concrete, masonry and soils. Deferred fire sprinklers and fire alarm with emergency evac voice equipment. Installation of all off-site improvements and street frontage landscaping during the first phase of construction. REF: PMT26-09582 for exterior modifications and landscape improvements. REF: PMT26-03552 Bldg improvement MEP and

6744 E BROADWAY RD · PMT25-21434

DUPLICATE CERTIFICATE OF OCCUPANCY. NAME CHANGE ONLY: REMNANT CITY CHURCH. 9009 SQ FT CHURCH ASSEMBLY - A3.1 OCCUPANCY WITH MAX 638 OCCUPANTS. 1384 SQ FT FOR BUSINESS AREA - B OCCUPANCY WITH MAX 4 OCCUPANTS. 195 SQ FT FOR EDUCATION AREA - E OCCUPANCY WITH MAX 6 OCCUPANTS. EXISTING TYPE III-B CONSTRUCTION. NO WORK UNDER THIS PERMIT. PREVIOUS RECORDS WERE FOR LIVING WORD CHURCH AT MISSION SQUARE. THE INTENTION OF THIS PERMIT IS TO DUPLICATE A PREVIOUSLY PERMITTED OCCUPANCY CLASSIFICATIONS ONLY. T

1933 E UNIVERSITY DR 19 · PMT26-03529

This project involves the "as-builting" of an existing condition and non-permitted construction that was executed by the previous building owner that subdivided an existing office suite into 2 separate suites that share the same electrical service. There is no "new" work anticipated outside of adding a security key box outside of the suites to allow access to the shared electrical panel as allowed by NEC 240.24(b) and approved by Mr. Chris Clark.

931 E SOUTHERN AVE 209 · PMT26-03161

Converting shower to shower, replacing pan, drain, and valves.

6436 E ARBOR AVE · PMT26-03490

Similar new_park_model Permits

Remove existing park Model 1983 Tara VIN # 1T9211123D1011063 - To install a new Park Model 2024 Cavco VIN # CFPUS3448R1210427 - 399SQ FT in SP#222 Douglas APN-140-34-485.

Mesa, AZ · PMT26-13565

PARK MODEL SET

Mesa, AZ · PMT26-13249

INSTALLATION OF 11FT - 2IN X 35FT - 4IN 2025 CAVCO PARK MODEL ABOVE GROUND SET. S/N. CFPUS3444T1211517. WITH A/C IN REAR. NO GAS OR LP TANKS. ONE 13FT - 6IN X 18FT ATTACHED AWNING PER ICCESR NO.1398. NO OTHER ACCESSORY STRUCTURES AT THIS TIME. MIN ONE 9FT X 18FT UNOBSTRUCTED PAVED PARKING SPACE REQUIRED BEHIND FRONT SETBACK. 46FT X 29FT INTERIOR CORNER LOT. MIN SETBACKS: 3FT FRONT MEASURED FROM EDGE OF ASPHALT, 5FT REAR, 3FT PARK MODEL SIDE & 0FT AWNING SIDE. APPROVED AS NOTED.

Mesa, AZ · PMT25-20790

INSTALLATION OF 11-FT-2IN X 33-FT-5IN 2026 CAVCO PARK MODEL WITH AC AT REAR AND UTILITIES. NO GAS OR LP TANKS. NO AWNING. NO OTHER ACCESSORY STRUCTURES AT THIS TIME. MIN ONE 9-FT X 18-FT UNOBSTRUCTURED PAVED 2-IN ASPHALT OR 4-IN CONCRETE PARKING SPACE REQUIRED BEHIND FRONT SETBACK. 33-FT2-IN X 64-FT1-IN INTERIOR LOT. MIN SETBACKS 4-FT, 5-FT REAR, 0-FT PARK MODEL SIDE, AND 3-FT AWNING/CARPORT SIDE. APPROVED AS NOTED.

Mesa, AZ · PMT25-22398

INSTALLATION OF A 2026 CAVCO EL PASO PARK MODEL 15.6-FT X 25.33-FT, VIN NO. CFPUS254XT1211319 WITH A 15.5-FT X 10-FT FACTORY PORCH. NO AWNING. AC LOCATED AT REAR. NO GAS/NO LP TANKS. INTERIOR LOT 33-FT X 50.5-FT. MINIMUM SETBACKS ARE 5-FT FRONT MEASURED FROM EDGE OF ASPHALT, 3-FT REAR, 18-IN SIDES FOR LOTS LESS THAN 35-FT WIDE. MININIMUM ONE 9-FT X 18-FT UNOBSTRUCTED PARKING SPACE BEHIND FRONT SETBACKS. MUST BE PAVED WITH 2-IN OF ASPHALT OR 4-IN CONCRETE. NO OTHER ACCESSORY STRUCTURES UNDER THI

Mesa, AZ · PMT26-09820

About new_park_model Permits in Mesa, AZ

What is a new_park_model permit?

A new_park_model permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.

How long does this permit remain valid?

Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.

Where does this data come from?

This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.