This project consists of 132-units multi-family development comprising of (5) 3-stories multifamily buildings and (1) 1-story clubhouse. BLDG 2: New 3-story, type V-B construction, 28,465 SF, group R-2 occupancy, 24-unit Multifamily building with 2hr fire rated wall to separate building. Special inspection required for steel, concrete, masonry, soils, post install anchors, Fire-resistant Penetrations & Joints, elect equip 1000amps. Deferred submittal - wood trusses. Deferred fire sprinklers
6147 E MAIN ST, Mesa, AZ
Permit Details
- Permit Number
- PMT26-07252
- Type
- multi-family_residential
- Status
- issued
- Issued Date
- July 9, 2026
- County
- Mesa, AZ
Parties
- Contractor
- Sara Davis
About multi-family_residential Permits in AZ
0
multi-family_residential permits in AZ
Other Permits in Mesa, AZ
New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi
3101 E ELMWOOD ST · PMT25-23465
Enclose entry porch to add powder room, move interior wall at garage to enlarge dining room, widen previously unpermitted patio cover to extend across back of house, add small attached storage shed and create enclosure for pool equipment. Additions result in 160 S.F. existing under roof remodeled into livable, and newly permitted 415 S.F. non-livable under new roof.
2461 S EXTENSION RD · PMT26-06531
TENANT IMPROVEMENT FOR AN INDOOR GOLF SIMULATOR IN EXISTING SPACE. THE PROJECT SCOPE IS DEMOLISHING EXISTING WALLS, FLOORING, CEILING, LIGHTING, HVAC DUCTWORK AND AIR DEVICES TO PREP FOR NEW GOLF SIMULATION AREAS BY ERECTING NEW INTERIOR WALLS, MECHANICAL AIR DISTRIBUTION AND POWER FOR GOLF SIMULATORS. PLUMBING IS EXISTING TO REMAIN.
2023 W GUADALUPE RD 11 · PMT26-12727
Build 572 SF detached ADU with architectural, and MEP. Meter
1622 W DALE CIR 101 · PMT26-08105
Scope of Work includes review for foundation inspections, structural steel package review, electrical package review and any special inspections for a privately owned substation. Special Inspections are required for concrete, soils, steel, and electrical installations. New typical substation prefabricated metal equipment enclosure, shipped to site in one piece.
7232 E ELLIOT RD · PMT26-08686
Similar multi-family_residential Permits
Building 8 R-2 occupancy V-A construction 15348 SF 78 occupants 12 apartments 1 1/2" water meter 1 elect. meter. Tile roofs, stucco finish, and post tension slabs. Deferred fire sprinklers (PMT22-06290C) and fire alarms (PMT22-06290B). Aerial apparatus access code modification: PMT23-13606. Civil work was completed in phase 1. Deferred fire sprinklers and fire alarm under PMT22-06290C and PMT22-06290B. As a result of C of O.
Mesa, AZ · PMT23-13935
Building 3 R-2 occupancy V-A construction 19112 SF 16 apartments, two 1 1/2" water meters 2 elect. meters Tile roofs, stucco finish, and post tension slabs. Deferred fire sprinklers and fire alarms. Aerial apparatus access code modification: PMT23-13606. See PMT23-14607 for civil work. As a result of C of O. Deferred fire sprinklers and fire alarm under PMT22-06290C and PMT22-06290B.
Mesa, AZ · PMT23-13948
New 144 units multi-family development comprising of 6, 3-stories buildings. Development includes detached single story leasing/clubhouse, maintenance building, mail ramada and BBQ ramada. R-2/ A-3 / B occupancies. Type VB and VA construction. Special inspection required for steel, concrete, masonry, wood, soils and anchoring. Water meters: (2) 2-inch domestic. Deferred fire sprinklers, fire alarms and vehicle gates. Civil under PMT24-03644. (Cover parking structures under separate permit.)
Mesa, AZ · PMT24-09658
Building 7 R-2 occupancy V-A construction 15348 SF 78 occupants 12 apartments 1 1/2" water meter 1 elect. meter. Tile roofs, stucco finish, and post tension slabs. Deferred fire sprinklers and fire alarms. Aerial apparatus access code modification: PMT23-13606. Civil work was completed in phase 1. Deferred fire sprinklers and fire alarm under PMT22-06290C and PMT22-06290B. As a result of C of O.
Mesa, AZ · PMT23-13937
Related to COB25-00112. Existing 3,472 SF apartment building built in 1983 with fire damage requiring repairs under IEBC Chapter 4. Original construction type V-B. Occupancy R-1 occupancy converts to R-2. To repair or reconstruction of a property damaged by fire, ensuring compliance with local building codes, zoning regulations, and safety standards. Deferred trusses. (4) electric meters. Special inspection for wood construction. This permit is limited to fire damage repair and replacement only
Mesa, AZ · PMT25-20007
About multi-family_residential Permits in Mesa, AZ
What is a multi-family_residential permit?
A multi-family_residential permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.
How long does this permit remain valid?
Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.
Where does this data come from?
This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.