Remove old existing meter/panel Install new 200A panel with main breaker
3160 E MAIN ST 55, Mesa, AZ
Permit Details
- Permit Number
- PMT26-01102
- Type
- mobile_home_other_addition
- Status
- finaled
- Issued Date
- June 9, 2026
- County
- Mesa, AZ
Parties
- Contractor
- Ronald J Andrus
About mobile_home_other_addition Permits in AZ
0
mobile_home_other_addition permits in AZ
Other Permits in Mesa, AZ
New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi
3101 E ELMWOOD ST · PMT25-23465
New 350 sq.ft. detached ADU at existing SFR. Truss calculations deferred. Minimum required building inspections: Footing, stem, strap/shear, frame, insulation, drywall shear and final. If needed, underground electrical and plumbing.
614 W ELENA AVE · PMT26-09900
Replacement of (40) RTUs on an existing 223,631 SF, construction type V-B Walmart. Scope includes structural modifications required and update to associated electrical. Special inspection for steel. Approved as noted. Any modifications to the fire protection systems will require a separate submittal. 2018 IFC 901.2. Results in CoC.
4505 E MCKELLIPS RD · PMT26-02448
Replace existing 5 meter combo with New Meter combo listed on the SRP Pre approved charts
719 N CHERRY · PMT26-07988
New 3,194 SF, construction type V-B, spec suite office building, with 24 SF canopy. Scope includes building and (3) suites, MEP's, and finishes. (3) new electric meters. Deferred fire Sprinklers, fire alarm, deferred truss calculations. Signage per separate permit by others. Results in CoO.
7165 E UNIVERSITY DR 103 · PMT25-14249
Similar mobile_home_other_addition Permits
Shed with Electric. Reference MH set PMT26-06833. No other accessory structures at this time. Minimum two 9-ft x 18-ft paved with 2-in of asphalt or 4-in of concrete unobstructed parking spaces are required behind front setback, one parking space required to be covered. 45-ft x 82.42-ft perimeter lot. Min setbacks are 5-ft front, 10-ft rear with 20-ft between awning and MH, 5-ft sides. Minimum required building inspections: Footing, stem, strap and shear, framing, underground electrical and fina
Mesa, AZ · PMT26-13891
My name is Victoria Tabakian, and I am assisting my mother Ophelia Baghtchedjian to finish the project that my father started on their house in Mesa back in 2021. My father, Hagop Baghtchedjian, got sick and eventually passed away before he could complete the Arizona room enclosure (to finish the space to be use as a living room, dining room and an office.) It was an Arizona room and he closed it up on the existing foundation. There is no plumbing work done and the few electrical elements my hus
Mesa, AZ · PMT26-14390
Remove existing carport and construct a new 240 SF livable addition with storage and laundry room area, a new 216 SF detached storage and 480 SF carport and a new 324 SF covered patio. Max lot coverage 50% BA02-01. Minimum of two 9-ft x 18-ft unobstructed paved, 2-in asphalt or 4-in concrete, parking space required behind front setback with a minimum of one covered. Minimum setbacks are 20-ft front, 15-ft rear, 5-ft sides. Accessory structure roof areas do not exceed the 100% MH floor area. Acce
Mesa, AZ · PMT26-05959
Mobile home room addition. 912 S.F. livable area. Truss calculations deferred. MH set PMT24-07582. Minimum required building inspections: Pre-demolition inspection to confirm non-load bearing walls, footing, stem, strap/shear, frame, insulation, drywall shear and final. If needed, underground electrical and plumbing.
Mesa, AZ · PMT25-09951
CITY OF MESA ZONING CLEARANCE PERMIT ONLY FOR INSTALLATION OF 30-FT X 64-FT 1977 ABOVE GROUND TRIPLE WIDE MH SET (VIN NUMBERS 031178CA13084A/B/C) WITH A/C AT REAR. NO GAS/NO LP TANKS. ONE (1) 10-FT X 36-FT ATTACHED AWNING. ENGINEERING PROVIDED BY CARL PUTNAM NO. 39702, EXPIRES 9/30/27. NO OTHER ACCESSORY STRUCTURES AT THIS TIME. MIN (2) 9-FT X 18-FT PAVED (2-IN ASPHALT OR 4-IN CONCRETE) UNOBSTRUCTED PARKING SPACES ARE REQUIRED BEHIND FRONT SETBACK (1) PARKING SPACE REQUIRED TO BE COVERED. 60-FT
Mesa, AZ · PMT25-02239
About mobile_home_other_addition Permits in Mesa, AZ
What is a mobile_home_other_addition permit?
A mobile_home_other_addition permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.
How long does this permit remain valid?
Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.
Where does this data come from?
This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.