PermitDig
commercial/industrial_projectsIn review

Construction of a new 4,975 SF, construction type V-B, B and S-1 occupancy, one-story Brakes Plus motor-vehicle repair facility consisting of customer sales/waiting, office and employee support areas, inventory/storage, and vehicle service bays. Work includes site improvements, foundations and structural, MEP's, vehicle lifts, automotive service equipment, and finishes. New (1) 1-inch landscape meter and (1) 2-inch domestic meter. Deferred fire sprinklers and prefabricated trusses. Special inspe

3508 S ELLSWORTH RD, Mesa, AZ

Permit Details

Permit Number
PMT26-11534
Type
commercial/industrial_projects
Status
in review
Issued Date
October 12, 2026
County
Mesa, AZ
View on county site

Parties

Contractor
Norm Herman

About commercial/industrial_projects Permits in AZ

0

commercial/industrial_projects permits in AZ

Other Permits in Mesa, AZ

New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi

3101 E ELMWOOD ST · PMT25-23465

Addition to existing Group I-2, Condition 2 rehabilitation hospital. Scope includes a new approximately 13,233-square-foot, construction type II-B, 20-bed patient-care addition: new smoke compartment and smoke barrier construction: associated patient rooms, support spaces, life-safety modifications, structural, MEP's, medical gas, and civil. Deferred fire sprinklers, fire alarm, access control, steel joists. Special inspection of steel, concrete, high-strength bolting, cold formed deck, post-ins

1702 S PIERPONT · PMT26-10466

Hawes Crossing Village 4 is a part of the Hawes Crossing master planned community located northeast quarter of Section 20, Township 1 South, Range 7 East of the Gila and Salt River Meridian. The Project is comprised of approximately 39 net acres planned for single family residential development. Approved with comments. Landscape meter included in Phase 1 under PMT25-03485.

8235 E WARNER RD · PMT26-10351

Modify existing fire alarm system by installing new panels and devices, which includes fire alarm control panels, NAC extension panels, initiating devices, notification appliances, smoke sensors standard and with sounder, addressable modules, duct smoke detectors, remote test stations, waterflow/tamper monitoring, and kitchen hood suppression system monitoring.

2122 E BROWN RD · PMT26-11700

CONSTRUCT 118 SQ FT STORAGE SHED UNDER EXISTING AWNING WITH CEILING JOIST, ELECTRIC AND PLUMBING. REFERENCE EXISTING PM SET PERMIT PMT20-13153. NO OTHER ACCESSORY STRUCTURES AT THIS TIME. THE EXISTING AWNING IS CONSIDERED A LEGAL NON-CONFORMING STRUCTURE PER MZO SECTION 11-36-4 AS IT EXCEEDS THE MAXIMUM SQUARE FOOTAGE ALLOWED PER MZO SECTION 11-34-2. THE STRUCTURE MAY REMAIN PROVIDED THAT NO EXPANSIONS OR ENLARGEMENTS ARE MADE, AND THE STRUCTURE IS NOT REMOVED OR DEMOLISHED. MINIMUM ONE 9-FT X 1

4700 E MAIN ST 427 · PMT26-11480

Similar commercial/industrial_projects Permits

Donor antenna is installed on the roof and takes signal to the BDA (Bio-Directional Amplifier) from riser. BDA then Amplifies the signal and sends it to the DAS (Distributed Antenna System). All coax cable will be installed in conduit per fire code. System will be monitored with 7 Supervisory signals sent to the Fire Alarm Control Panel from BBU (Battery Back Up) Annunciator Panel.

Mesa, AZ · PMT26-13246

Installation of access control devices at one existing second-floor interior door, Hub-1DR-003. Existing mechanical hardware to remain and provide free egress at all times. Related to PMT26-01450. Reviewed as noted. Results in CoC.

Mesa, AZ · PMT26-12177

Installation of Phase 1 access control devices at multiple existing and new door openings, including electric strikes, electromagnetic locks, door monitoring devices, and associated access-control equipment. Existing mechanical hardware to remain and provide free egress as applicable. Ref: PMT25-21107. Reviewed as noted. Results in CoC.

Mesa, AZ · PMT26-12164

Existing building. Install iron site fencing, (2) manual roller vehicle gates, and (2) manual man gates. Associated with PMT26-11732, same scope of work for adjacent property. Approved as noted. Results in CofC.

Mesa, AZ · PMT26-13797

Development of 229,416 SF, Type II-B construction, groups B and S-1 occupancy single story data center. The development building is designed with tilt wall construction. The building will have supported chiller cooling platforms on south and north side of the buildings. Special Inspections Req - Emergency Responder Radio Coverage IFC 510. Special inspection required - Fire -Resistance Penetration and Joints, concrete, steel, masonry, anchors & bolts, soils, hi-pot testing. Deferred - stairs & pl

Mesa, AZ · PMT26-15404

About commercial/industrial_projects Permits in Mesa, AZ

What is a commercial/industrial_projects permit?

A commercial/industrial_projects permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.

How long does this permit remain valid?

Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.

Where does this data come from?

This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.