One additional 1600A SES section is for SES C2 and one additional 1600A SES section for SES C3. Equipment permitted under PMT26-00351. (2) new electric meters. Special inspection for electrical. Reviewed as noted. Results in CoC.
8341 E PECOS RD, Mesa, AZ
Permit Details
- Permit Number
- PMT26-09424
- Type
- commercial/industrial_projects
- Status
- issued
- Issued Date
- June 8, 2026
- County
- Mesa, AZ
Parties
- Contractor
- Tiffany Hartono
About commercial/industrial_projects Permits in AZ
0
commercial/industrial_projects permits in AZ
Other Permits in Mesa, AZ
New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi
3101 E ELMWOOD ST · PMT25-23465
Install one illuminated channel letters, on backer panel, mounted onto existing screen wall XPO 32 Sq Ft. Signs shall be installed per NEC 2023 with UL listed components.
7360 S SOSSAMAN RD · PMT26-10820
New single-story 400 SF livable detached ADU. Type V-B construction. Deferred truss calculations. No special inspections. Minimum required building inspections: Plumbing underground, footing, stem, strap/shear, frame, mechanical rough in, electric rough in, plumbing rough in, insulation, drywall shear, mechanical final, electric final, plumbing final and final.
944 S MACDONALD · PMT26-11504
Install three temp banners 07/17/26-12/19/26
2920 N POWER RD 109 · PMT26-12349
adding a gas line to an existing line. The new gas line with be a 2" PE pipe buried no less than 20" with a tracer wire and will connect to the existing 1.5" PE pipe that feeds the 400k pool heater. the new gas line will feed four 20k btu natural gas torches. Ref. PMT26-09824 for the Pergola I will also be installing a 2" PE pipe that will tie into a nipple coming out of the back of the house and will feed a 60k btu natural gas BBQ, a 65k btu natural gas fire pit, and a 20k btu natural gas tor
3408 E IVYGLEN CIR · PMT26-11529
Similar commercial/industrial_projects Permits
New construction of a 1,114 SF, type VB construction, group B occupancy Dutch Bros Coffee Stand with 834 SF of Canopy for (1) drive-thru window and (1) walk-up service window. No indoor seating or interior access to the public. Site development include a small parking area, (2) drive aisles and a trash enclosure. Special inspection req for Masonry, Wood and Soils. Exist 2-inch domestic meter to be relocated. Deferred Roof trusses. Deferred fire sprinklers and CO2 monitoring. Results in CoO.
Mesa, AZ · PMT26-05704
The project consists of the development of a new shops building and the associated paved access, parking, utility, and drainage infrastructure.
Mesa, AZ · PMT26-12926
Front of the property will have 331' of 58" tall wrought iron fencing. Material will be 1 5/8 top and bottom rail. 3/4" pickets. 2 1/2 x 2 1/2 post. There will be two 24' rolling gates that are 58" tall. Material: 2x2 3/4x14 Guage frame. 1" pickets. 3 1/8x11 gauge pinch roller post. There will also be two 48" wide man gates. 1 5/8x 1 5/8 frame. 3/4" pickets. 2 1/2x 2 1/2 post. Gravity latch. Back of the property will have 20' of 70" tall wrought iron fencing. Material: 2x2 top and bottom rail.
Mesa, AZ · PMT26-13797
NTT Global Data Centers Americas is adding an additional Data Center building in Mesa, Arizona as part of a 244MW master planned site. PH6 will consist of 8 vaults with prefabricated UPS electrical power modules, generators and closed loop air-cooled chillers located on the exterior. The initial buildout will consist of a core and shell, underground utilities and equipment pads, and a single 8 MW vault with 56 MW future vaults 2 through 8. The envelope will consist of tilt up concrete panels wit
Mesa, AZ · PMT26-13890
New one-story parish office building that replaces the current facility to serve the existing campus. New building program includes: public lobby vestibule, conference rooms, breakroom, private office spaces for administration offices as well as private offices for adult-religious education offices, a teen life classroom. All existing fire lanes remain and existing entry / exit driveways remain. Minor landscape and site development includes: new concrete sidewalks and points of connection to ent
Mesa, AZ · PMT26-14315
About commercial/industrial_projects Permits in Mesa, AZ
What is a commercial/industrial_projects permit?
A commercial/industrial_projects permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.
How long does this permit remain valid?
Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.
Where does this data come from?
This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.