PermitDig
commercial/industrial_projectsIssued

TI to enclose 4,648 SF construction type II-B batting cages and new 3,114 SF construction type II-B for pitching lab addition. Scope includes 1-hour fire rated assembly between the existing training facility and the batting cages structure. Limited occupancy for the new pitching lab. MEP's, structural, civil, landscaping, and finishes. Documentation demonstrating the tunnel netting complies with the applicable interior finish requirements, including the flame spread index and smoke-developed ind

160 E ATHLETICS WAY, Mesa, AZ

Permit Details

Permit Number
PMT26-08519
Type
commercial/industrial_projects
Status
issued
Issued Date
July 6, 2026
County
Mesa, AZ
View on county site

Parties

Contractor
Liya Chandy

About commercial/industrial_projects Permits in AZ

0

commercial/industrial_projects permits in AZ

Other Permits in Mesa, AZ

New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi

3101 E ELMWOOD ST · PMT25-23465

COB26-00040 Repairs of fire damaged home. No change to overall square footage. Truss calculations deferred. Special inspections required for drill & epoxy. Minimum required building inspections: Framing and final.

301 W 9TH PL N · PMT26-08445

Tub to Shower in Hall Bathroom at existing SFR - Replace existing wet space with new shower including new valve and prefabricated acrylic walls. No structural changes - will tie into existing piping. No change to overall square footage.

2438 E JEROME AVE · PMT26-11437

PERMIT IS ONLY FOR INSTALLATION OF ONE TESLA POWERWALL 3 BATTERY. ALL WORK TO BE PERFORMED PER 2024 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEES

8056 E MADERO AVE · PMT26-11349

Interior renovation of the Macayou's restaurant at the AZA Airport into a Cold Beer and Cheeseburgers. The work requires demo and rebuild of dining area, new bar and new storage room. Deferred fire sprinklers, fire alarm and hood fire suppression.

6033 S SOSSAMAN RD · PMT26-09126

Similar commercial/industrial_projects Permits

Existing facility. Install coolant pump skid with electrical control board at vehicle assembly line. Results in CofC.

Mesa, AZ · PMT26-11451

Install new equipment and relocate existing equipment in existing facility. Relocate (3) existing car hoist. Install new air compressors, (2) car hoists, pallet wrap machine, and portal crane. Tie into existing plumbing water supply line for new ice-maker and car rinse. Special inspections required: concrete construction, steel construction, and high-strength bolts. Results in CofC.

Mesa, AZ · PMT26-11447

**BUILDING 11**Development of light industrial business, complex comprising story buildings. (2) two-suites Type VB construction, 12,674 SF, Canopy 710, SF. S-1: 10,026 SF B: 2,290 SF. Water meters (1-inch domestic). Special inspections required for concrete, steel, expansion and epoxy anchors, welding, masonry and soils. DEFERRED FIRE SPRINKLERS. DEFERRED FIRE ALARM. REF: PMT24-15326 for Civil and landscape, REF: PMT24-15327 for primary permit. Results in CofO.

Mesa, AZ · PMT24-20554

Ground up Community Center with offices, kitchen, gathering area, and storage. Onsite PMT25-08440. Deferred fire sprinklers and hood fire extinguishing system.

Mesa, AZ · PMT25-23753

Structural improvements consisting of enlargement of existing reinforced concrete spread footings supporting existing structural steel columns in an occupied tilt-up commercial building. Work includes selective demolition, excavation, reinforcing steel installation, concrete placement, temporary shoring, and restoration per engineered drawings.

Mesa, AZ · PMT26-12243

About commercial/industrial_projects Permits in Mesa, AZ

What is a commercial/industrial_projects permit?

A commercial/industrial_projects permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.

How long does this permit remain valid?

Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.

Where does this data come from?

This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.