Construction of additional living space.
1348 E GABLE CIR, Mesa, AZ
Permit Details
- Permit Number
- PMT26-10991
- Type
- accessory_dwelling_units
- Status
- revisions required
- Issued Date
- July 1, 2026
- County
- Mesa, AZ
Parties
- Contractor
- CRANDALL ERIC L/JENNIFER K
About accessory_dwelling_units Permits in AZ
0
accessory_dwelling_units permits in AZ
Other Permits in Mesa, AZ
New Master Plan Blandford Homes #4503 – Encanto. 3615 S.F livable, 1208 S.F. non-livable. Two story with a 2 car garage. Elevation options A, B, F, G, H, I, and J. Options second flr at elev. B and J +95 S.F. non-livable pop outs and balcony. Options for a 2 ft and 4 ft ext at garage. Option for a smaller loft -75 S.F livable. Options on floorplan are Den or Bedroom 7 at dining. Den at bedroom 6. Other options of Fireplace, Walk-in-Shower, enlarged bedroom 2 and 5, bedroom 2 at loft, and multi
3101 E ELMWOOD ST · PMT25-23465
COB26-00040 Repairs of fire damaged home. No change to overall square footage. Truss calculations deferred. Special inspections required for drill & epoxy. Minimum required building inspections: Framing and final.
301 W 9TH PL N · PMT26-08445
Tub to Shower in Hall Bathroom at existing SFR - Replace existing wet space with new shower including new valve and prefabricated acrylic walls. No structural changes - will tie into existing piping. No change to overall square footage.
2438 E JEROME AVE · PMT26-11437
PERMIT IS ONLY FOR INSTALLATION OF ONE TESLA POWERWALL 3 BATTERY. ALL WORK TO BE PERFORMED PER 2024 IRC, MANUFACTURE’S INSTALLATION INSTRUCTIONS AND SERVICE UTILITY PROVIDER SPECIFICATIONS. PERMIT DOES NOT INCLUDE PHOTOVOLTAIC SYSTEM INSTALLATION. DO NOT DISCONNECT UTILITY WIRES OR METERS. SCHEDULE DISCONNECT/RECONNECT WITH THE SERVING UTILITY AND OBTAIN UTILITY SERVICE REQUIREMENTS SPECIFIC TO YOUR SCOPE OF WORK. FAILURE TO SCHEDULE DISCONNECT MAY RESULT IN ADDITIONAL UTILITY TRIP CHARGE FEES
8056 E MADERO AVE · PMT26-11349
Interior renovation of the Macayou's restaurant at the AZA Airport into a Cold Beer and Cheeseburgers. The work requires demo and rebuild of dining area, new bar and new storage room. Deferred fire sprinklers, fire alarm and hood fire suppression.
6033 S SOSSAMAN RD · PMT26-09126
Similar accessory_dwelling_units Permits
-NEW DETACHED 817 SQ.FT. ACCESSORY DWELLING UNIT CONSISTING OF 2 BEDROOMS, 2 BATHROOMS, AND A FULL KITCHEN. -ADU WILL HAVE A NEW 100 AMP SUB-PANEL, AND CENTRAL HVAC UNIT.
Mesa, AZ · PMT26-11911
we will be converting a 21x21 porch into an ADU
Mesa, AZ · PMT26-12889
Building a 24' x 24' building in the rear yard to be utilized as a GYM.
Mesa, AZ · PMT26-13148
Approximately 790 SF structure , 1 Bedroom,1 Bathroom with 208 SF non livable custom built in trussing covered patio cover. 9' Ceilings. Exterior finishes and roof tile will match the existing house.
Mesa, AZ · PMT26-11831
ADU Detached – New 930 SF livable detached accessory dwelling unit and 128 SF non livable covered patio. Type V construction. R5 occupancy. Deferred truss calculations. No special inspections. Includes a new 200A electric service panel. Minimum required building inspections: Footing, stem, strap/shear, frame, insulation, drywall shear, underground electrical and plumbing. Final.
Mesa, AZ · PMT26-05462
About accessory_dwelling_units Permits in Mesa, AZ
What is a accessory_dwelling_units permit?
A accessory_dwelling_units permit authorizes specific construction or renovation work at a property. It ensures the work meets local building codes and safety standards. Most jurisdictions require permits for structural changes, electrical work, plumbing, roofing, and demolition.
How long does this permit remain valid?
Permit validity varies by jurisdiction. In Mesa, AZ, permits typically remain valid for 6-12 months from the issue date. Contact the local building department for specifics.
Where does this data come from?
This permit record comes from Mesa, AZ's public records, sourced via their open data portal. All building permit data in the US is public record. PermitDig aggregates this data to make it searchable.